background image

 

 
 

 

 

P/N: 2900-300868 Rev 1 

www.KramerAV.com

 

USER MANUAL 

MODEL: 

TP

580TD, TP

580RD  

DVI Line Transmitter / Receiver 

             

 

 

Summary of Contents for TP-580RD

Page 1: ...P N 2900 300868 Rev 1 www KramerAV com USER MANUAL MODEL TP 580TD TP 580RD DVI Line Transmitter Receiver ...

Page 2: ... the TP 580TD DVI Line Transmitter 4 Defining the TP 580RD DVI Line Receiver 5 Connecting the TP 580TD TP 580RD DVI Line Transmitter Receiver 6 Wiring the HDBT RJ 45 Connectors 7 Controlling A V Equipment via an IR Remote Control 7 Connecting to TP 580TD TP 580RD via RS 232 8 Technical Specifications 9 Default Communication Parameters 9 ...

Page 3: ...and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your Kramer TP 580TD and TP 580RD away from moisture excessive sunlight and dust This equipment is to be used only inside a building It may only ...

Page 4: ...ble wiring connectivity with protection against unintentional cable disconnection HDMI Signal Extension HDMI 2 0 and HDCP 2 2 compliant via single link DVI I connection Supports deep color x v Color lip sync HDMI uncompressed audio channels Dolby TrueHD DTS HD 2K 4K and 3D EDID signals are passed through from the source to the display I EDIDPro Kramer Intelligent EDID Processing Intelligent EDID p...

Page 5: ...deal for the following typical applications Medical operation rooms and other critical AV extension applications Highly reliable long distance extension of high quality professional AV signals via lockable cable connections Governmental high reliability AV extension applications Rental and Staging events ...

Page 6: ...shed with the HDBaseT receiver ON LED Lights green when the device receives power HDBT OUT RJ 45 Connector Connect to the HDBT IN connector on a receiver for example TP 580RD DVI IN Connector Connect to a DVI source PROG NORMAL Switch Slide to PROG to upgrade to the latest Kramer firmware via RS 232 or slide to NORMAL for normal operation RS 232 3 pin Terminal Block Connector Connect to a laptop t...

Page 7: ...tter ON LED Lights green when the device receives power HDBT IN RJ 45 Connector Connect to the RJ 45 HDBT OUT connector on a transmitter for example TP 580TD DVI OUT Connector Connect to a DVI acceptor PROG NORMAL Switch Slide to PROG to upgrade to the latest Kramer firmware via RS 232 or slide to NORMAL for normal operation RS 232 3 pin Terminal Block Connector Connect to a laptop to control TP 5...

Page 8: ... Line Transmitter Receiver 1 Connect a DVI source for example a Blu ray player to the DVI IN connector 2 Connect the DVI OUT connector to the DVI acceptor for example a display 3 On the TP 580TD connect the RS 232 3 pin terminal block connector to the RS 232 port of a controller device for example the Kramer SL 240C 4 On the TP 580RD connect the RS 232 3 pin terminal block to the device to be cont...

Page 9: ...ng a peripheral device for example a Blu ray disk player to send commands from the receiver system to the transmitter or to send commands from the transmitter system to the receiver To use an IR remote control transmitter connect the Kramer IR sensor cable at one end and the Kramer IR emitter cable at the other end The example in Figure 3 illustrates how to control a Blu ray player that is connect...

Page 10: ...can be used to Extend serial communication data between serial enabled devices that are connected to the TP 580TD and TP 580RD Upgrade the firmware of the TP 580TD and or TP 580RD using a Laptop PC or other serial enabled controller devices Connect the RS 232 terminal block on the rear panel of the TP 580TD TP 580RD to a PC controller as follows see Figure 4 TX pin to Pin 2 RX pin to Pin 3 GND pin...

Page 11: ...115200 Control RS 232 Baud Rate 115200 Enclosure Size DigiTOOLS Type Aluminum Cooling Convection ventilation Power Source 12V DC 2A Consumption TP 580TD 12V DC 275mA TP 580RD 12V DC 450mA Environmental Conditions Operating Temperature 0 to 40 C 32 to 104 F Storage Temperature 40 to 70 C 40 to 158 F Humidity 10 to 90 RHL non condensing General Product Dimensions 12 00cm x 7 15cm x 2 44cm 4 72 x 2 8...

Page 12: ...by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up this product any adjustment of user controls or any programming required...

Page 13: ...ARNING Disconnect the unit from the power supply before opening andservicing For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback ...