KRAMER: SIMPLE CREATIVE TECHNOLOGY
Communication Protocol
16
9 Communication
Protocol
This protocol, which enables RS-232 communication between the
SP-10D
and the PC, uses 4 bytes of information, and data is at 9600 baud.
Table 6: Protocol Definitions
First byte options
DEC
HEX
1 128 80
RESET
VIDEO
2 160 A0
READ
PARAMETER
3 161 A1
WRITE
PARAMETER
4 162 A2
RECALL
5 163 A3
STORE
6 189 BD
IDENTIFY
MACHINE
7
33
21
Set (for the rest of commands)
Second byte is the command type
Third byte is the parameter value
Note:
1. When working in HEX, add 80 to the values in the table.
2. When working in DEC, add 128 to the values in the table.
3. All values in the table are in DEC.
Byte 2 Command Description
Byte 3 (parameter value)
0
INPUT FORMAT
0 - CV
1 - YC
2 - YUV
3 - RGB/S
4 - SDI
1
INPUT_STANDARD
0 - PAL B
1 - PAL N
2 - PAL M
3 - NT 3
4 - NT 4
5 - SEC
6
–
AUTO
(READ 19 - INPUT_STANDARD_AUTO)
2
SPLITTER
-100 - +100
3
SHARP_H
0 - 15
4
SHARP_V
0 - 15
5
CONTRAST
-100 - +100
6
BRIGHTNESS
-100 - +100
7
VIDEO_GAIN
-100 - +100
8
H_SHIFT
-16 - +15
9
V_SHIFT
-1 - +1
10
Y
-100 - +100
11
U
100 - +100
12
V
100 - +100
13
GREEN
-100 - +100
14
BLUE
-100 - +100
15
RED
-100 - +100
16
COLOR
-100 - +100
17
HUE
-100 - +100
18
COLOR_SPACE
0 - OFF
1 - YUV
2 - RGB
19 INPUT_STANDARD_AUTO
(READ
ONLY)
0 - PAL B
1 - PAL N
2 - PAL M
3 - NT 3
4 - NT 4
5 - SEC