![Kramer SL-280 User Manual Download Page 54](http://html1.mh-extra.com/html/kramer/sl-280/sl-280_user-manual_2000924054.webp)
Kramer Electronics Ltd.
SL-280 – Protocol 3000
52
IR-SND
Functions
Permission
Transparency
Set:
IR-SND
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Send IR command to
port
#
IR-SND
␠
PortNum,Cmd_id,CmdName,Repeat,
TotalPackets,PacketNum,<pronto command…>
␍
Get:
-
-
Response
~nn@
IR-SND
␠
PortNum,Cmd_id,CmdName,Status
␍␊
Parameters
PortNum
– IR port transmitting the command:
1
–
8
,
*
(broadcast to all ports)
Cmd_id
– command ID, numeric string of up to 9 digits for flow control and response commands from
device
CmdName
– command name, string of up to 15 alpha-numeric characters
Repeat
– number of times the IR repeat command is transmitted
1
(default) –
50
(repeats >
50
are
truncated to
50
)
TotalPackets
– number of messages the original command was divided into, default =
1
PacketNum
– chunk serial number (only valid when
Total_packets
> 1),
PacketNum
must be <=
TotalPackets
.
Pronto command
– Pronto format command (in HEX format, no leading zeros, no ‘0x’ prefix, values must
be separated by commas)
Status
–
0 (
no error)
Response Triggers
Notes
Example
Transmit IR Power button command with ID of 25 and name PowerTog from port 1; command is repeated 1
time, the total packets is 1,packet/chunk serial number is 1:
#IR-SND
1,25,PowerTog,1,1,1,0000,006e,0022,0002,0156,00ae,0016,0016,0016,0041,0016,0016
,0016,0041,0016,0016,0016,0016,0016,0016,0016,0016,0016,0016,0016,0041,0016,001
6,0016,0041,0016,0016,0016,0016,0016,0016,0016,0016,0016,0016,0016,0041,0016,00
16,0016,0041,0016,0016,0016,0016,0016,0016,0016,0016,0016,0041,0016,0016,0016,0
041,0016,0016,0016,0041,0016,0041,0016,0041,0016,0041,0016,069c,0156,0057,0016,
0e56
<CR>