MV-6 - Protocol 3000 Commands
57
Command -
OVRLBK
Command Type - Multiviewer
Command Name
Permission
Transparency
Set:
OVRLBK
End User
Public
Get
OVRLBK?
End User
Public
Description
Syntax
Set:
Set text overlay background parameters
#
OVRLBK
␠
stage, stage_id,r,g,b,alpha
␍
Get:
Get text overlay background parameters
#
OVRLBK?
␠
stage, stage_id
␍
Response
~ nn@
OVRLBK
␠
stage, stage_id,r,g,b,alpha
␍␊
Parameters
stage -
input/output - set reference to
Section
stage_id
- number of chosen stage (1.. max number of inputs/outputs)
r -
red component value (0-255)
g -
green component value (0-255)
b -
blue component value (0-255)
alpha -
alpha value (0-255)
Response Triggers
After execution, response is sent to the com port from which the Set/Get
was received
After execution, response is sent to all com ports if OVRLBK
was set by any other external control device
(button press, device menu and similar)
Notes