50
MV-6 - Protocol 3000 Commands
Command -
NAME
Command Type - System (Ethernet)
Command Name
Permission
Transparency
Set:
NAME
Administrator
Public
Get:
NAME?
End User
Public
Description
Syntax
Set:
Set machine (DNS) name
#
NAME
␠
machine_name
␍
Get:
Get machine (DNS) name
#
NAME?
␍
Response
Set: ~nn@
NAME
␠
machine_name
␠
OK
␍␊
Get: ~nn@
NAME?
␠
machine_name
␍␊
Parameters
machine_name
- String of up to 14 alpha-numeric chars (can include hyphen, not at the beginning or end)
Response Triggers
Notes
The machine name is not the same as the model name. The machine name is used to identify a specific
machine or a network in use (with DNS feature on)
Command -
NAME-RST
Command Type - System (Ethernet)
Command Name
Permission
Transparency
Set:
NAME-RST
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset machine (DNS) name to
factory default
#
NAME-RST
␍
Get:
-
-
Response
~nn@
NAME-RST
␠
OK
␍␊
Parameters
Response Triggers
Notes
Factory default of machine (DNS) name is “KRAMER_” + 4 last digits of device serial number