Kramer Electronics Ltd.
FC-404NETxl
– Protocol 3000
36
Protocol 3000 Commands
Function
Description
Syntax
Parameters/Attributes
Example
#
Protocol handshaking.
Validates the
Protocol 3000
connection and gets the
machine number.
Step-in master products
use this command to
identify the availability
of a device.
COMMAND
#
<CR>
FEEDBACK
~nn@
ok
<CR><LF>
#
<CR>
BEACON-
INFO?
Get beacon
information, including
IP address, UDP
control port, TCP
control port, MAC
address, model, name.
There is no Set
command. Get
command initiates a
notification.
COMMAND
#BEACON-INFO?
port_id
<CR>
FEEDBACK
~nn@BEACON-INFO
port_id
,
ip_string
,
udp_port
,
tcp_port
,
mac_
address
,
model
,
name
<CR><LF>
port_id
– ID of the Ethernet port
ip_string
– Dot-separated
representation of the IP address
udp_port
– UDP control port
tcp_port
– TCP control port
mac_address
– Dash-separated
mac address
model
– Device model
name
– Device name
Get beacon information:
#BEACON-INFO?
<CR>
BUILD-
DATE?
Get device build date.
COMMAND
#BUILD-DATE?
<CR>
FEEDBACK
~nn@BUILD-DATE
date
,
time
<CR><LF>
date
– Format: YYYY/MM/DD
where
YYYY = Year
MM = Month
DD = Day
time
– Format: hh:mm:ss where
hh = hours
mm = minutes
ss = seconds
Get the device build date:
#BUILD-DATE?
<CR>
CONF-
EXPORT
For Kramer internal use
only.
CONF-
IMPORT
For Kramer internal use
only.
DSP-METER
Register DSP meters.
Internal
– for web only.
DSP-
METER?
Read DSP meters.
COMMAND
#DSP-
METER
<direction_type>
.
<port_type>.<port_index>.<signal_t
ype>.<index>
,
type
<CR>
FEEDBACK
~nn@DSP-METER
<direction_type>
.
<port_type>
.
<port_index>
.
<s
ignal_type>
.
<index>
,
type,value
<CR><LF>
▪
<direction_type>
–
o
IN
o
OUT
▪
<port_type>
–
o
ANALOG_AUDIO
o
ANALOG_JACK
o
DANTE
▪
port_index>
– The port
number as printed on the front
or rear panel: 1 to 4 for analog
audio, and 1 for Dante
▪
signal_type>
– Signal ID
attribute:
o
AUDIO
▪
<index>
– Indicates a specific
channel number when there
are multiple channels of the
same type: 1 to 4 for Dante,
and 1 for Analog audio
value
–
[dBFS]
Read the limiter value on the
output:
#DSP-METER
OUT.ANALOG
_STEREO.1.AUDIO.1
,
5
<CR
>
DSP-
METER-
REGISTER
Register DSP meters.
Internal
– for web only.
ETH-PORT
Set Ethernet port
protocol.
If the port number
you enter is already in
use, an error is
returned.
The port number must
be within the following
range: 0-(2^16-1).
COMMAND
#ETH-PORT
port_type
,
port_id
<CR>
FEEDBACK
~nn@ETH-PORT
port_type
,
port_id
<CR><LF>
port_type
– TCP/UDP
port_id
– TCP/UDP port number
(0
– 65535)
Set the Ethernet port
protocol for TCP to port
12457:
#ETH-PORT
0
,
12457
<CR>
ETH-PORT?
Get Ethernet port
protocol.
COMMAND
#ETH-PORT?
port_type
<CR>
FEEDBACK
~nn@ETH-PORT
port_type
,
port_id
<CR><LF>
port_type
– TCP/UDP
0
– TCP
1
– UDP
port_id
– TCP / UDP port number
(0
– 65535)
Get the Ethernet port
protocol for UDP:
#ETH-PORT?
1
<CR>
FACTORY
Reset device to factory
default configuration.
This command
deletes all user data
from the device. The
deletion can take some
time.
Your device may
require powering off
and powering on for the
changes to take effect.
COMMAND
#FACTORY
<CR>
FEEDBACK
~nn@FACTORY
ok
<CR><LF>
Reset the device to factory
default configuration:
#FACTORY
<CR>