Kramer Electronics Ltd.
FC-404NETxl
– Technical Specifications
34
Default Communication Parameters
RS-232
Baud Rate:
115,200
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format:
ASCII
Example (set analog input 3 audio level to 10):
IN
.
ANALOG_AUDIO
.
3
.
AUDIO
.
1
,
10
<CR>
Ethernet
DHCP ON by default
IP Address:
192.168.1.39
Subnet mask:
255.255.255.0
Default gateway:
192.168.0.1
TCP Port #:
5000
UDP Port #:
50000
Default username:
Admin
Default password:
Admin
Device name:
FC-404Net-
{ID} where ID = the last 4 characters of the device’s serial number.
Dante
DHCP OFF by default
IP Address:
169.254.112.120
Subnet mask:
255.255.0.0
Default gateway:
169.254.0.0
Full Factory Reset
Webpages
Go to: Device Settings-> General -> RESET
Protocol 3000:
“
#factory
” command followed by “
#reset
” command.