Kramer Protocol 3000
51
Command -
SN?
Command Type - System-mandatory
Command Name
Permission
Transparency
Set:
-
-
-
Get:
SN?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get serial number
#
SN?
␍
Response
~nn@
SN
␠
serial_number
␍␊
Parameters
serial_number
- 11 decimal digits, factory assigned
Response triggers
Notes
For new products with 14 digit serial numbers, use only the last 11 digits
Command -
TIME
Command Type - System
Command Name
Permission
Transparency
Set:
TIME
Administrator
Public
Get:
TIME?
End User
Public
Description
Syntax
Set:
Set device time and date
#
TIME
␠
day_of_week,date,time
␍
Get:
Get device time and date
#
TIME?
␍
Response
~nn@
TIME
␠
day_of_week, date, time
␠
OK
␍␊
Parameters
day_of_week
- one of {SUN,MON,TUE,WED,THU,FRI,SAT}
date
- Format: DD-MM-YYYY.
time
- Format: hh:mm:ss
Response triggers
Notes
The year must be 4 digits
The device does not validate the day of week from the date
Time format - 24 hours
Date format - Day, Month, Year
Summary of Contents for FC-21ETH
Page 2: ......
Page 28: ...24 Remote Operation via the Web Pages Figure 14 General Info Page...
Page 59: ......