31
KPS-MT60 • Digital multimeter
ENG
Pass Hz grade
Range
Resolution
Accuracy
66Hz
0,01Hz
±(1,5% of r 5 digits)
660Hz
0,1Hz
6,6kHz
0,001kHz
66kHz
0,01kHz
660kHz
0,1kHz
6,6MHz
1kHz
66MHz
10kHz
- Overload protection: 250V DC or AC (RMS)
- Measurement signal: Vpp3V AC signal
Duty radio
Range
Resolution
Accuracy
10 - 95%
0,1%
± 2,0%
DC Current
Range
Resolution
Accuracy
660uA
0,1uA
±(1,0% of r 5 digits)
6600uA
1uA
66mA
10uA
660mA
100uA
10A
10mA
±(2,0% of r 5 digits)
uA and mA grade: Fuse FF600mA/1000V, A grade: Fuse FF10A/500V.
When measuring current is greater than 5A, the continuous measurement time
should not be more than 10 seconds. After measuringe, disconnect the current.