34
KPS-PA50 MINI • Digital clamp meter
ENG
- Response: true root mean square value
INRUSH Current
Range
Resolution
Accuracy
66A
0,01A
<60A take it only as referance
± (10.0% of rdg + 60 digits)
600A
0,1A
- Integration Time: 100ms
- Measurement range: 30 ~ 600A
- Max. input current: 600A
- Frequency range: 40 to 400Hz
- Response: true root mean square value
DC Current
Range
Resolution
Accuracy
66A
0,01A
±(3,0% of 10 digits)
600A
0,1A
- Max. input current: 600A DC
DC Voltage
Range
Resolution
Accuracy
660mV
0,1mV
± (0,8% of r 3 digits)
6,6V
0,001V
66V
0,01V
600V
0,1V
± (1,0% of r 5 digits)
- Input impedance: 10MΩ
- Overload protection: 660mV range: 250V DC or rms AC, 6.6V-600V ranges:
600V DC or 600V rms AC.
- Max. input voltage: 600V DC
Note:
At small voltage range, unsteady readings will appear before the test leads