36
KPS-PA50 MINI • Digital clamp meter
ENG
Escala
Resolución
Precisión
660Hz
0,1kHz
±(1,5% of r 5 digits)
6,6kHz
0,001kHz
10kHz
0,01kHz
>10kHz
0,01kHz
Take it only as referance
- Measurement range: 10 ~ 10kHz
- Input voltage range: ≥ 0.2V rms AC (higher input voltage at higher frequency)
- Input impedance: 10MΩ
- Max. input voltage: 600V rms AC
Duty Cycle
Range
Resolution
Accuracy
10 - 95%
0,1%
± 3,0%
•
By A range ( from current clamp):
- Frequency response: 10 ~1kHz
- Input current range: ≥1A rms AC (higher input current at higher frequency)
- Max. input current: 600A
•
By V range:
- Frequency response: 10 ~ 10 kHz
- Input voltage range: ≥ 0.2V rms AC (higher input voltage at higher frequency)
- Input impedance: 10MΩ
- Max. input voltage: 600V rms AC