25
KPS-PA40 • Digital clamp meter
ENG
DC Voltage
Range
Resolution
Accuracy
0,4V
0,1mV
±0,7% of reading ± 1 digit
4V
1mV
40V
10mV
400V
0,1mV
1000V
1V
±0,8% of reading ± 3 digits
-Input impedance: 10MΩ
-Overload protection: 1000V CC or 700V CA RMS
AC Voltage
Range
Resolution
Accuracy
0,4V
0,1mV
±0,8% of reading ± 5 digits
4V
1mV
40V
10mV
700V
0,1V
±1,0% of reading ± 10 digits
Input impedance: 10MΩ
Frequency range: 400Hz to 400Hz
Overload protection: 1000V CC or 700V CA RMS
DC Current
Range
Resolution
Accuracy
400A
0,1A
± (3,0% of r 3 digits)
1000A
1A
Overload protection:
120% ranges for 60 secons max.