27
KPS-PA40 • Digital clamp meter
ENG
Frequency Measurement
Range
Resolution
Accuracy
40Hz
0,01Hz
±(2,0% of r 1 digit)
400Hz
0,1Hz
4Hz
1Hz
40Hz
10Hz
100Hz
0,1kHz
- Measurement range: 1V to 10V rms. 10Hz to 100kHz.
Temperature
Range
Resolution
Accuracy
400°C~750°C
1ºC
±(1,0% of r 3 digit)
0°C~400°C
1ºC
±(1,0% of r 3 digit)
-40°C~0°C
1ºC
±(1,0% of r 3 digit)
Audible Continuity and Diode
Range
Description
If continuity exists (about less than 30), built-in buzzer will
sound.
Show the approx. Forward voltage of the diode.
Duty cycle: 0,1% to 99,9%
10. AUTO POWER OFF
To extend the battery life, Auto Power Off function is provided.If no key oper
tions of range changing happen about 15 minutes,the meter will be turned off
automatically. To turn it on,rotate the rotary switch or push any function buttons
only.