kozy heat windom 56101 Installation And Operating Manual Download Page 21

LIGHTING & SHUTDOWN 

 

NOTE: Prior to lighting, check all fittings for leakage. This is accomplished by applying soapy water on all 
connections made. If there is any leakage, bubbles will appear at the point of connection. If bubbles occur, 
tighten the fittings until the bubbles no longer appear. 

 

IMPORTANT:

 TEST ALL CONNECTIONS WHETHER FIELD OR FACTORY MADE. 

NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system 
during any pressure testing of that system at test pressures in excess of ½ psi. 

 

NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut 
off valve during any pressure testing of the gas line at test pressures equal to or less than 1/2 psig (3.5 kPa). 

 

Pressure check taps for the manifold (outgoing) and inlet (incoming) pressures are located in front of the gas 
valve. The left pressure tap is the manifold pressure and the right pressure tap is the incoming pressure. Follow 
instructions on page #28 for checking these pressures. 

 

FOR YOUR SAFETY - READ BEFORE LIGHTING 

 

 

WARNING:

   If you do not follow these instructions exactly, a fire or explosion may result causing property 

damage, personal injury or loss of life. 

 

 

1.  This appliance has a pilot which must be lighted by hand. 

When lighting the pilot, follow these instructions exactly. 

2.  BEFORE LIGHTING, smell all around the appliance for 

gas. Be sure to smell next to the floor because some gas is 
heavier than air and will settle on the floor. 

3.  Use only your hand to push in or turn the gas control knob. 

Never use tools. If the knob will not push in, or turn by 
hand, don’t try to repair it, call a qualified service 
technician. Forced or attempted repair may result in a fire 
or explosion, and loss of warranty. 

4.

 

Do not use this appliance if any part has been under water. 
Immediately call a qualified service technician to inspect 
the appliance and to replace any part of the control system 
which has been under water.

 

 

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS 
AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

DUE TO HIGH SURFACE TEMPERATURES, KEEP CHILDREN, 
CLOTHING AND FURNITURE AWAY. 

This appliance needs fresh air for safe operation and 
must be installed so there are provisions for adequate 
combustion and ventilation air. 

WHAT TO DO IF YOU SMELL GAS: 

 

*  Do not touch electrical switches. 
*  Do not try to light any appliance. 
*  Do not use any phone in your building. 
*  Follow the gas supplier’s instructions. 
*  Immediately call your gas supplier from a neighbor’s 

phone. 

* If you cannot reach your gas supplier, call the fire 

department.

 

 
 

 

1.  STOP! Read safety information above. 
2.  Open the lower grill by grasping the center of the top louver, then pull out and down to access the gas valve. 
3.  Set the thermostat to the lowest setting. (If installed) 
4.  Turn off all electric power to the appliance. (Fan) 

 

5.  Push in black control knob (A) slightly and turn clockwise        to "OFF".  

 

NOTE: Knob cannot be turned from "PILOT" to "OFF" 
unless knob is pushed in slightly. Do not force. 

LIGHTING INSTRUCTIONS

Gas valve

 

 

6.  Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow the safety information on 

page 20. If you don't smell gas, go to the next step. 

 

Pilot

7.  Find the pilot - follow metal tube from gas control. The pilot is behind the burner tube.  

 

8.  Turn the black control knob (A) on the gas valve counterclockwise        to "PILOT". 

Page 19

Summary of Contents for windom 56101

Page 1: ...must be performed by a qualified installer service agency or the gas supplier MODEL 56101 WINDOM DIRECT VENT GAS FIREPLACE INSTALLATION AND OPERATING MANUAL This appliance may be installed in an afte...

Page 2: ...ed heating appliance or equipment The sign shall read in print size no less than inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state of local gas inspector of the...

Page 3: ...S 10 REMOVE THE GLASS ASSEMBLY 11 DIRECT VENT CHIMNEY INSTALLATION 11 FAN INSTALLATION 12 13 GAS LINE SPECIFICATIONS 14 15 SECURE THE MILLIVOLT BOARD 15 LOG INSTALLATION 16 THERMOSTAT WALL SWITCH REMO...

Page 4: ...Current Edition SPECIFICATIONS Height front 32 Height back 30 1 8 Front width 36 Back width 23 3 8 Depth 11 Flue size 4 exhaust 6 5 8 combustion air intake PASS THRU WALL THICKNESS The Dura Vent DV G...

Page 5: ...ance and to replace any part of the control system and any gas control which has been under water CONSULT YOUR LOCAL OR NATIONAL INSTALLATION CODES TO ASSURE THAT ADEQUATE COMBUSTION AND VENTILATION A...

Page 6: ...IPE TO FINISHED WALL REQUIRED 1 Clearance at sides 1 Clearance at sides 2 1 4 1 54 3 4 38 5 8 KOZY HEAT CORNER CABINET INSTALLATION MODEL 56101 WINDOM CORNER CABINET DIMENSIONS FIGURE 2C MODEL 56101 W...

Page 7: ...MPORTANT Consult the local and national installation codes to assure that adequate combustion and ventilation air is available MINIMUM MAXIMUM VENTING REQUIREMENTS Minimum vertical rise maximum horizo...

Page 8: ...ide inside corner 12 F 7 Meter Regulator not to be installed above within 3 ft horizontally from the center line of the regulator 8 Service regulator vent outlet 3 ft radius 9 Electrical box 3 ft G DO...

Page 9: ...tion cap Maximum horizontal run 14 ft 1 4 incline for each horizontal foot of chimney must be maintained WALL THIMBLE 6 22 3 8 TO CENTER OF VENT PIPE 26 TO TOP OF VENT PIPE 1 CLEARANCE AT THE TOP FOR...

Page 10: ...rmation WHEN VERTICALLY TERMINATING THE MINIMUM CHIMNEY HEIGHT ABOVE THE ROOF LINE IS DETERMINED BY THE FOLLOWING CHART Roof Pitch Minimum Chimney Height Roof Pitch Minimum Chimney Height Flat to 6 12...

Page 11: ...in compliance with the guidelines on page 6 of this manual 2 Determine the width depth and height of the optional hearth NOTE A hearth is not required If a hearth is desired combustible materials may...

Page 12: ...ir around the unit Air enters the unit at the lower grill and exits at the upper grill Blocking these passages may result in overheating the fireplace creating a potentially hazardous situation 6 Plac...

Page 13: ...age from the firebox and set aside HORIZONTAL VERTICAL VENTING APPLICATIONS 1 INSTALL THE CHIMNEY SYSTEM FOR YOUR VENTING CONFIGURATION FOLLOWING THE CHIMNEY MANUFACTURERS INSTRUCTIONS INCLUDED WITH T...

Page 14: ...includes 1 Right and left fan assemblies with fans with temperature control switch 2 Components Package Speed control with mounting bracket nut knob installation instructions NOTE To wall mount the s...

Page 15: ...wiring with ground through the romex connector installed in the electrical box and wire to the receptacle 6 Secure receptacle into the electrical box 7 Install the cover onto the electrical box and s...

Page 16: ...ffixed to the flexible tubing for additional installation instructions and warnings NOTE For high altitude installations consult the local gas distributor or the authority having jurisdiction for prop...

Page 17: ...rom the gas supply piping system during any pressure testing of that system at test pressures in excess of psi NOTE The appliance must be isolated from the gas supply piping system by closing its indi...

Page 18: ...remaining base logs W6 W7 into the center of the burner as shown Natural Gas models Push the logs back against the burner tube 3 Carefully place the rock wool embers as desired onto the logs and burne...

Page 19: ...es from the top bottom terminals on the gas valve Follow instructions included with the remote control Remote Control Wiring Diagram CAUTION DO NOT CONNECT HIGH VOLTAGE 115V WIRE TO THE GAS VALVE REMO...

Page 20: ...embly to the fireplace by pulling the two spring loaded handles located under the firebox out and up over the latch brackets Release locking them into position 4 Upper Grill Install A Line the rods of...

Page 21: ...t push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in a fire or explosion and loss of warranty 4 Do not use this appliance if an...

Page 22: ...e top louver then pull out and down to access the gas control valve 2 Set the thermostat to the lowest setting If installed 3 Turn off all electric power to the appliance if service is to be performed...

Page 23: ...s turned on NOTE If manifold pressure reading is within the normal range an incoming pressure check is not necessary A too high or too low pressure reading warrants an inlet incoming gas pressure chec...

Page 24: ...eplace the logs glass and upper grill The flow of combustion and ventilation air must not be obstructed IMPORTANT ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING T...

Page 25: ...t the manual shut off valve 3 Disconnect gas line flex tube from the manual shut off valve 4 Disconnect any wall switch remote control or thermostat wires from the top bottom terminals on the gas valv...

Page 26: ...assembly and tighten 3 Install the burner tube by positioning it over the burner orifice and aligning the mounting holes at the sides of the burner tube onto the tabs on the millivolt board 4 Position...

Page 27: ...USE SOLUTION 1 No spark when piezo Piezo wire connection at valve Push wire back into place button is depressed is loose or off Wire from piezo to electrode is Reconnect wire loose at electrode Electr...

Page 28: ...and tighten screws Generator wire grounded out Nuts securing millivolt board may need due to pinched wires loosening to remove pinched wire Generator is not producing enough Check millivolt reading re...