20
FACING AND FINISHING
8.2 Shroud Installation
CAUTION: Trim panels or surrounds must not seal ventilation
openings in existing fireplace that this appliance is installed in.
Draft relief openings must not be covered or blocked.
WARNING: The flow of combustion and ventilation air must not
be obstructed.
For shrouds JXL-27040, JXL-30042, JXL-33046, JXL-CUS, and
JXL-ACUS.
1. Remove glass frame assembly.
2. Align leg section holes on the shroud to the corresponding
mounting nuts in mounting brackets on each side of the
insert metal cabinet.
3. Secure with (4) phillips truss head screws (provided).
4. Reinstall glass frame assembly.
8.3 Safety Barrier Installation
For safety barriers J34-PSF, J34-RSF, J34A-MSF, J34A-PSF,
J34A-SF, J34A-FPDSF, J34-CXF, and J34-BSF.
1. Locate the (4) slots on the glass frame (2 each side).
2. Align the tabs located on the back of the safety barrier with
the slots on the glass frame.
3. Raise the safety barrier slightly into the slots and allow the
tabs to lower into position.
• To remove safety screen: lift the screen up and out of slots.
Figure 8.3, Aligned Mounting Nuts and Brackets