background image

36

  REPLACEMENT PARTS LIST

15.0  REPLACEMENT PARTS LIST

Replacement parts are available through your local dealer. Contact your local dealer for availability and pricing. 

CONTROL BOARD AND PARTS

Control Board - NG

J30-160 Valve Step Motor - LPG

700-504-1

Control Board - LPG

J30-161 18 in. Flexible Gas Line - Black

700-213B

S.I.T. IPI Gas Valve - NG

700-567 Flexible Gas Line - Valve to Burner Connection

700-226

S.I.T. IPI Gas Valve - LPG

700-567-1 NG Burner Orifice #53 FRONT

700-253

Proflame 2 IFC Board

700-652 NG Burner Orifice #44 BACK

700-244

IFC Wire Harness Assembly

700-653 LPG Burner Orifice #61 FRONT

700-261

Pilot Assembly - NG

700-551 LPG Burner Orifice #55 BACK

700-255

Pilot Assembly - LPG

700-551-1 Conversion Kit - NG

NCK-J30-S

540 Split Flow 

700-595 Conversion Kit - LPG

LCK-J30-S

Transmitter (Remote Control) with Split flow

700-508 Front Burner

J30-350

Pilot Orifice - NG #62

700-166 Back Burner

J30-351

Pilot Orifice - LPG #35

700-168 Battery Holder

700-419

Valve Step Motor - NG

700-504

LOG SET

8 Piece Log Set

J30-500

Ember Panel

J30-900E

#1 Log

J30-1

#2 Log

J30-2

#3 Log

J30-3

#4 Log

J30-4

#5 Log

J30-5

#6 Log

J30-6

#7 Log

J30-7

#8 Log

J30-8

Rock Wool Embers

900-REMB

GLASS AND GLASS PARTS

Glass with Gasket 255/8” x 17½”

JOR-057T

Valance

JOR-005

Glass Gasket

900-006

Hussong Manufacturing Co., Inc.  
P.O. Box 577 
204 Industrial Park Drive 
Lakefield, MN 56150-0577
JOR-30S

SAFETY BARRIERS

Beveled Screen Front

J30-BSF

Convex Screen Front

J30-CXF

Prairie Screen Front

J30-PSF

Rectangular Screen Front

J30-RSF

Arched Mission Screen Front

J30A-MSF

Arched Prairie Screen Front

J30A-PSF

Arched Screen Front

J30A-SF

Arched Full Prairie Door Screen Front

J30A-FPDSF

Summary of Contents for JOR-30S

Page 1: ...injury death or property damage This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is o...

Page 2: ......

Page 3: ...r safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeown...

Page 4: ......

Page 5: ...CONNECTION 18 7 1 Gas Conversion sold separately 18 7 2 Gas Line Installation 18 8 0 FACING AND FINISHING 19 8 1 Clearances to Combustibles 19 8 2 Shroud Installation 20 8 3 Safety Barrier Installatio...

Page 6: ......

Page 7: ...s shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimu...

Page 8: ...D3333 1313 2 2 Heating Specifications Natural Gas LP Gas Maximum Input Rating 30 500 Btu h 8 9 kW 30 500 Btu h 8 9 kW Minimum Input Rating 12 000 Btu h 3 5 kW 11 000 Btu h 3 2 kW Manifold Pressure Hig...

Page 9: ...767 Opening Width D 26 1 4 666 Back Width E 24 3 8 619 Depth F 15 5 8 397 Height to Air Duct Top G 21 1 8 537 Unit Bottom to Gas Line Access H 14 1 8 360 Back to Gas Line Access I 1 1 4 32 Unit Bottom...

Page 10: ...e to use only specified approved parts with this appliance may result in property damage or personal injury Table 2 2 Field Assembled Parts A Fireplace insert F Back burner assembly B Module panel ass...

Page 11: ...ced with Hussong Mfg s barriers for this appliance Only doors certified with the appliance shall be used Please refer to Section 8 3 Safety Barrier Installation on page 20 for installation instruction...

Page 12: ...16 in 406 mm D Back Width 245 16 in 618 mm If installing the JOR FLP add 1 in 25 mm total dimension of floor protector and airspace to height to maintain minimum existing fireplace height opening requ...

Page 13: ...appliance must not share or be connected to a chimney flue serving a separate solid fuel burning appliance Approved vent caps require 12 in 305mm clearance to intersecting walls overhangs or eaves as...

Page 14: ...to Section 7 0 Gas Line Connection on page 18 If the factory built fireplace has no gas access hole s provided an access hole of 1 in 37 5 mm or less may be drilled through the lower sides or bottom...

Page 15: ...pipe will have a red marking IMPORTANT Maximum horizontal vent runs of 24 in 609 mm require a 1 in 25mm rise per 12 in 305 mm run Care should be taken when installing the flexible vent pipes to avoid...

Page 16: ...mination cap into position as instructed by vent system manufacturer s installation manual OPTIONAL Kozy Heat 816 CL Secure termination cap to existing chimney with 2 in 50 mm self tapping screws and...

Page 17: ...e an air tight seal AIR DUCT Figure 6 4 Air Duct in Existing Fireplace FLEXIBLE PIPES SHEET METAL SCREWS 3 TOTAL SEALANT SEALANT 6 5 Place and Secure Appliance 1 Slide the gas fireplace insert into ex...

Page 18: ...be isolated from the gas supply piping system by closing its individual manual shut off valve A listed and Commonwealth of Massachusetts approved in 13 mm tee handle manual shut off valve and flexible...

Page 19: ...servicing and proper operation must be maintained COMBUSTIBLE MATERIAL 3 76mm CLEARANCE TO ADJACENT SIDEWALL Hearth Protection X Clearance to Combustible Floor Y 0 in 0 mm 5 in 127 mm 4 in 102 mm 2 1...

Page 20: ...orresponding mounting nuts in mounting brackets on each side of the insert metal cabinet 3 Secure with 4 phillips truss head screws provided 4 Reinstall glass frame assembly 8 3 Safety Barrier Install...

Page 21: ...hile lowering the bottom of the glass assembly into position 2 Using the glass latch tool pull latches out and down over latch tabs to secure glass frame assembly bottom Figure 9 1 Lower Latch 1 each...

Page 22: ...ustrations for proper log placement 1 Place the ember panels behind the front burner ports as shown below 2 Align the holes in the bottom of logs J30 1 and J30 2 with the mounting pins on the back bur...

Page 23: ...side 7 Remove front burner assembly by lifting it up and off the front burner orifice 8 Remove 10 screws securing the control board on the left side of the firebox 9 Pull out control board out to rev...

Page 24: ...remove the grounding prong from this plug 10 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes wi...

Page 25: ...appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIONS NOTE When this fireplace is initially lit conde...

Page 26: ...ialized 6 Slide the control module access switch to ON position for remote control operation of the main burner and fireplace features Figure 11 1 Battery Holder Box and Battery Holder Clips 11 3 Rese...

Page 27: ...oximately 2 seconds move the switch to the ON position The ignition sequence will start again 11 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key to turn the system OFF 2 After ap...

Page 28: ...ng pilot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption When the system is OFF the LCD scre...

Page 29: ...can be set to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The LCD screen will display a temperature bulb graphic the room temperature...

Page 30: ...time for heat to build in fireplace before fan operation The fan will continue to operate for approximately 12 minutes after the fireplace has been turned off Manual mode Fan s will operate at previo...

Page 31: ...ximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Relight pi...

Page 32: ...Venturi Opening Adjustment NOTE If soot is present on the glass check log positioning before adjusting the venturi Logs must not block burner ports IMPORTANT Slight adjustments to the venturi opening...

Page 33: ...o LP propane gas in tank Check LP propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe or a...

Page 34: ...mix Refer to Section 12 2 1 Burner Venturi on page 32 Incorrect vent cap installation Adjust if necessary Vent cap blockage Remove debris if necessary Flame burns blue and lifts off burner Improper ve...

Page 35: ...System NOTE If the vent air intake system is disassembled for any reason reinstall per instructions provided with installation Section 6 0 Installation on page 15 Performed by Qualified Service Perso...

Page 36: ...0 S 540 Split Flow 700 595 Conversion Kit LPG LCK J30 S Transmitter Remote Control with Split flow 700 508 Front Burner J30 350 Pilot Orifice NG 62 700 166 Back Burner J30 351 Pilot Orifice LPG 35 700...

Page 37: ...ng Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole obligati...

Page 38: ......

Page 39: ...efective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective firepla...

Reviews: