Page 10
DO NOT ATTEMPT TO TIE ONE ROPE AROUND BOTH PIPES.
A. Guide the rope, if used, and flexible pipes down the existing
chimney. Figure E-2
B. To secure the chimney termination cap to the existing
chimney, apply a liberal bead of sealant (provided) around the
top of the existing chimney. Set the termination cap into
position as instructed in the vent system installation manual.
OPTIONAL: #816-CL kits - Secure the termination cap to the
existing chimney with the 2" self-tapping screws and anchor
straps provided. Screw holes are located at the sides of the
termination cap.
C. From inside the opening, grasp the ropes and CAREFULLY
pull the ropes until the 3” combustion air intake and 3” exhaust
pipes are down into the existing fireplace.
ˆ
OPTIONAL: We recommend placing non-faced fiberglass
batting insulation between the pipes and existing chimney to
prevent heat loss up the chimney. (See Figure E-3)
Figure E-3
Figure E-2
OPTIONAL:
PLACE NON-FACED FIBERGLASS BATTING INSULATION
BETWEEN THE PIPES AND EXISTING CHIMNEY TO
PREVENT HEAT LOSS UP THE CHIMNEY.