background image

LIMITED WARRANTY 

41

LIMITED WARRANTY

Kozy Heat Limited 10 Year Warranty

This limited 10 Year Warranty will not become effective until the 
Warranty Registration Form has been completed and mailed to 
Hussong Manufacturing Co., Inc., P.O. Box 577, Lakefield, MN 
56150. This registration form must be received within 30 days 
of installation. Failure to do so may result in delayed warranty 
coverage and submission of proof of purchase will be required.

Hussong Manufacturing Co., Inc. warranties to the original 
purchaser of this Kozy Heat Fireplace, that it is free of defects in 
materials and workmanship at the time of manufacture.

Subject to the following conditions & requirements, Hussong 
Manufacturing Co., Inc. extends the following limited warranty 
under normal use and service, with respect to the Kozy Heat line of 
gas burning fireplaces.

Year 1

Subject to the conditions & requirements listed below, within the 
first year from date of purchase, Hussong Manufacturing Co., Inc. 
shall, at its discretion, replace or repair any such defect in  material 
or workmanship, at Hussong Manufacturing Co., Inc.’s expense, 
including reasonable labor costs to repair or replace the defective 
component, if a factory pre-authorization is given for the repair. 

Years 2 through 10

Subject to the conditions & requirements listed below, beginning 
with the first day of the second year and continuing through the 
tenth year, Hussong Manufacturing Co., Inc., will at its discretion, 
provide repair or replacement parts at current list prices for any 
defect in material or workmanship of components, including 
optional components and accessories (if available). Hussong 
Manufacturing Co., Inc. shall not be  responsible for any installation, 
labor, transportation of other indirect costs.

Limitation of Liability

To make a claim under this warranty, the purchaser must first 
contact the dealer/installer from whom the fireplace was purchased.

This limited warranty will be void if the fireplace is not installed by a 
qualified installer and according to the installation instructions. Use 
of unauthorized components will make this warranty null and void.

This limited warranty also is void if the fireplace is not operated, at 
all times, according to the operating instructions furnished.

This warranty is limited to defects in material and workmanship. It 
does not apply to any product that has been subject to negligence, 
misapplication, improper installation. 

No person is authorized to extend the time of this warranty or to 
accept on Hussong Manufacturing Co., Inc.’s behalf any additional 
obligation of liability connected with the unit. 

It is expressly agreed and understood that this warranty is Hussong 
Manufacturing Co., Inc.’s sole obligation and purchaser’s exclusive 
remedy for defective fireplace equipment. Hussong Manufacturing 
Co., Inc. shall not be liable for any consequential, incidental or 
contingent damages whatsoever. The foregoing warranty is 
exclusive and in lieu of all other expressed warranties. Hussong 
Manufacturing Co., Inc. shall not be held to implied warranties or 
merchantability and fitness for a particular purpose. This warranty 
replaces all previous warranty policies.

Some states do not allow the exclusion or limitation of incidental 
or consequential damages or limitations on how long an implied 
warranty lasts, so the above limitations or exclusions may not apply 
to you. This warranty gives you specific legal rights and you may 
also have other rights which vary from state to state.

Hussong Manufacturing Co., Inc. reserves the right to make changes 
at any time, without notice, in design, material, specifications and 
prices. Hussong Manufacturing Co., Inc. reserves the right to 
discontinue models and products.

September 2011

Warranty Conditions and Requirements

1.  You are the original purchaser. This warranty is not transferable.

2.  Installation of the fireplace is performed by a qualified installer.

3.  Installation and operation must comply with installation and operation instructions.

4.  Paint and glass gaskets are covered for 30 days from date of purchase.

5.  Remote controls and all optional accessories are covered for 1 year from date of purchase.

6.  This warranty does not offer coverage for Light Bulbs or Batteries (whether factory, dealer or installer supplied). This includes 

any damage stemming from either component’s nonuse.

7.  Components broken, (including glass panels), during shipping, careless handling of components, or defects resulting from 

improper installation, misuse of the fireplace and components are not covered under this warranty.

8.  This warranty does not cover any part of the fireplace or any components which have been exposed to or submerged 

underwater. 

9.  Hussong Manufacturing Co., Inc. must be notified by the dealer the fireplace was purchased from or a qualified installer/service 

technician of the defect. 

10.  Annual service of the fireplace as required in the installation manual, is performed by a qualified installer/service technician.   

(Copies of such service records may be required to claim a warranty). 

11.  All previous warranty/service has been performed by a qualified installer or service technician.  

(Copies of such service records may be required to claim a warranty).

Summary of Contents for BAY-36-MV

Page 1: ...ed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate...

Page 2: ......

Page 3: ...r safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeown...

Page 4: ......

Page 5: ...18 6 2 Minimum Termination Clearances 19 7 0 VENTING 20 7 1 Rear Vent Conversion Instructions 20 7 2 Venting Requirements 22 7 3 Approved 4 x 6 Vent Systems 22 7 4 Vent Clearances 22 7 5 Use of Elbow...

Page 6: ...accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanently mounted to the...

Page 7: ...a 6 4 WC 1 59 kPa Orifice Size DMS 42 53 2 2 1 Altitude Adjustment This appliance may be installed at higher altitudes Please refer to National Fuel Gas Code ANSI Z223 1 NFPA 54 CSA B149 1 Natural Gas...

Page 8: ...to Rear Vent Center Inches 32 35 3 4 18 7 8 15 13 16 32 5 8 26 13 16 10 7 7 8 25 7 8 Millimeters 813 907 479 401 829 681 254 199 657 18 7 8 479mm 7 7 8 199mm 15 13 16 401mm 10 254mm 26 13 16 681mm 32...

Page 9: ...ptions TOP AND SIDES OVERLAP NO OVERLAP INSIDE FIT TOP AND SIDES OVERLAP TOP AND SIDES OVERLAP TOP AND SIDES OVERLAP TOP AND SIDES OVERLAP TOP AND SIDES OVERLAP B36 PSF B36 FRSF B36R MSF B36A MSF B36R...

Page 10: ...top stand offs provide the 10 in 254 mm minimum clearance to the header Use only non combustible material in this area for the entire width of the fireplace DO NOT use wood sheetrock et cetera in thi...

Page 11: ...chamber Provide adequate clearance in front of the fireplace for barrier removal component access gas line installation service access et cetera Framing dimensions should allow for wall covering thic...

Page 12: ...codes Outside walls should be insulated to prevent cold air from entering room Follow vent pipe manufacturer s installation instructions for vertical terminations A minimum of 1 in 25 mm clearance on...

Page 13: ...TYPICAL CORNER INSTALLATION TOP VENT TYPICAL HORIZONTAL INSTALLATION REAR VENT 36 920mm 1 25mm 15 7 8 403mm INCLUDES TYPICAL FINISH MATERIAL WITH FLUSH MOUNT 36 920mm 26 673mm 1 25mm TYPICAL VERTICAL...

Page 14: ...g away from the fireplace 3 Secure the nailing flanges to the fireplace with screws provided through the slots in nailing flanges 4 Bend perforation on nailing flange until parallel with fireplace fac...

Page 15: ...FACING AND FINISHING 15 4 2 Mantel Requirements 13 343mm 15 394mm 17 445mm 14 356mm 12 305mm 9 229mm 13mm NON COMBUSTIBLE MATERIAL ONLY FIREPLACE ENCLOSURE FLOOR 45 1156mm SINGLE VERTICAL HEADER...

Page 16: ...screen front until the notched tabs are firmly in position verifying the depth accommodates finish material To remove safety screen lift the screen up and out of slots 4 3 3 Overlap Fit Direct Mount...

Page 17: ...Pa For test pressures equal to or less than psi 3 5 kPa the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve A listed and Commonwealth of Ma...

Page 18: ...2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2 27 Over 20 12 to 2...

Page 19: ...ce 12 in 30 cm 9 in 23 cm K Clearance to mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally Massachusetts 10 ft 3 m L Clearance above paved sidewalk or paved dri...

Page 20: ...ctions below to be used NOTE All components removed from the top vent exit will be reinstalled for the rear vent 7 1 1 Remove Top Vent Collars 1 REMOVE 7 SCREWS SECURING COVER PLATE 2 REMOVE 4 SCREWS...

Page 21: ...GASKET IS IN PLACE UNDERNEATH SECURE WITH 6 SCREWS PREVIOUSLY REMOVED 2 INSTALL 6 168mm COMBUSTION AIR INTAKE COLLAR TO REAR VERIFY GASKET IS IN PLACE SECURE WITH 4 SCREWS PREVIOUSLY REMOVED 3 SECURE...

Page 22: ...imney Horizontal Vertical Selkirk Direct Temp Horizontal Vertical Simpson DuraVent DirectVent Pro EXCEPT Snorkel 46DVASNK14 Horizontal Vertical 7 4 Vent Clearances NOTE Wall thimble products that comp...

Page 23: ...tion Venting Table 7 4 NG LPG Minimum Vertical Maximum Horizontal Minimum Vertical Venting Minimum Horizontal Run Maximum Horizontal Run 90 elbow off appliance top 6 in 152 m 8 ft 2 4 m Table 7 5 NG L...

Page 24: ...corresponding screw holes located in front of the flue outlet on the top of the fireplace 3 Secure the vertical vent heat shield to the fireplace with 2 attachment screws provided in the components p...

Page 25: ...l to Vertical Venting Minimum Vertical Length Maximum Vertical Length 90 elbow off appliance back 3 ft 914 mm 50 ft 15 2 m Table 7 8 NG Max Vertical Max Horizontal Combination Maximum Vertical Rise Ma...

Page 26: ...rtical Venting Minimum Vertical Length Maximum Vertical Length 90 elbow off appliance back 3 ft 914 mm 50 ft 15 2 m Table 7 11 LPG Max Vertical Max Horizontal Combination Maximum Vertical Rise Maximum...

Page 27: ...25 mm top clearance and 1 in 25 mm side clearance to the exterior wall and seal OPTIONAL insulate the wall thimble with any unfaced insulation products listed as non combustible per ASTM E 136 3 Apply...

Page 28: ...ith a receptacle box cover assembly in the fireplace components packet Kit Components 1 133 CFM fan with temperature control switch 1 Remove the safety barrier safety barrier and log set 2 Remove burn...

Page 29: ...G WIRING 110 120 V 60 Hz LEGEND A Black hot from incoming line B Black from speed control C White neutral from incoming line D White neutral from receptacle E Ground bare from incoming line F Ground g...

Page 30: ...e bottom of each log Refer to the following instructions and illustrations for proper log placement 1 Position the ember panel in front of the burner 2 Align the holes in the bottom of base logs B36 1...

Page 31: ...crews 8 Remove burner assembly 2 screws on each side 9 Remove the burner heat shield 3 screws located at the back of the firebox 10 Remove and save 8 screws securing the control board 11 Lift the cont...

Page 32: ...115V wire to the gas valve If desired a thermostat a wall switch or a remote control assembly may be installed to enable ON OFF control of the main burner Only one of these components may be installed...

Page 33: ...nd any gas control that has been under water LIGHTING INSTRUCTIONS 1 STOP Read all the safety information above on this page 2 Set thermostat to lowest setting if applicable 3 Turn off all electric po...

Page 34: ...s near maximum inlet pressure 6 Press the rocker switch to OFF 7 Turn the gas control knob to OFF 8 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snu...

Page 35: ...f soot is present on the glass check log positioning before adjusting the venturi Logs must not block burner ports 1 Remove the safety barrier and glass frame assembly 2 Remove the log set the back lo...

Page 36: ...ualified service technician If it is determined that a restrictor is needed or restrictor modification is required after the vent termination is installed access can be reached by removing the firepla...

Page 37: ...roper flame impingement Loose thermocouple connection Ensure thermocouple connection at gas valve is full inserted and tight hand tight plus 1 4 turn Thermocouple reading below 15 millivolts Disconnec...

Page 38: ...panels with high temperature sealant especially around the intake duct Pilot and burner extinguish while in operation No LP gas in tank Check LP propane tank Refill if necessary Incorrect glass frame...

Page 39: ...e Person Frequency Every 6 months Action Disconnect the fans from electrical current and vacuum The bearings are sealed and require no oiling 13 3 Vent System NOTE If the vent air intake system is dis...

Page 40: ...0 Conversion Kit NG OCK S42A Flexible Pilot Tubing valve to pilot 700 099 Conversion Kit LPG OCK S53A Millivolt Generator 700 092 Log Plate B36L 351 Thermocouple 700 093 SAFETY BARRIERS Full Rectangul...

Page 41: ...ssong Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole oblig...

Page 42: ......

Page 43: ...f the defective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective...

Reviews: