38
ELECTRICAL INFORMATION
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#ALP-36 R.7 January 2020
9.3 Light Kit
CAUTION: Disconnect all electrical power from the fireplace before
performing this task.
NOTE: To avoid damage and prolong the life of the halogen bulbs,
never touch with bare hands. Always use a soft cloth when handling.
9.3.1 Install Light Kit
1. Remove the safety barrier and glass frame assembly.
2. Remove the light access panel on firebox ceiling (2) screws.
3. Using a 1/4” wrench, loosen, but do not remove, the bulb clips
located inside the light chamber.
4. Install (2) halogen bulbs (included in components packet) into
lamp bases.
5. Reposition bulb clips over tips of halogen bulbs and re-tighten
screws. Do not over-tighten.
6. Reinstall light access panel on firebox ceiling using (2) screws
previously removed.
Figure 9.2, Light Kit Access Panel Location
LIGHT ACCESS PANEL - SECURED BY (2) SCREWS
Figure 9.3, Bulb Clips