3
SPECIFICATIONS
ATTENTION
HIGH ALTITUDE INSTALLATIONS
In the USA:
The appliance may be installed at higher altitudes. Please refer to your American Gas Association
guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000ft. (610m)
is to be reduced 4% for each 1000ft. (305m) above sea level. Refer also to National Fuel Gas Code, ANSI Z223.1/ NFPA
54, local authorities, or codes which have jurisdiction in your area regarding the de -rate guidelines.
In Canada:
When the appliance is installed at elevations above 4500ft. (1372m), the certified high altitude rating shall
be reduced at the rate of 4% for each additional 1000ft. (305m). Refer also to CSA-B149.1 Natural Gas and Propane
Installation Code, Local authorities, or codes which have jurisdiction in your area regarding the de-rate guidelines.
COMPONENTS LIST
NATURAL GAS
LP GAS
MINIMUM INLET GAS PRESSURE
5” WC (1.25 kPa) (7” WC (1.74 kPa) recommended)
12” WC (2.99 kPa) (recommended)
MAXIMUM INLET GAS PRESSURE
10.5” WC (2.62 kPa)
13” WC (3.24 kPa)
MANIFOLD PRESSURE (HI)
3.8” WC (.95 kPa)
11” WC (2.74 kPa)
MANIFOLD PRESSURE (LO)
1.1” WC (.27 kPa)
2.9” WC (.72 kPa)
ORIFICE SIZE
#29
#49
INPUT BTU/hr. (kW)
48,000 BTU/hr (14.07 kW)
48,000 BTU/hr (14.07 kW)
MINIMUM INPUT BTU/hr. (kW)
24,000 BTU/hr (7.03 kW)
24,000 BTU/hr (7.03 kW)
PART NUMBER
DESCRIPTION
AL36-L-150
Control Board Assembly
700-203
Manual Gas Shut-off Valve
AL36-500
Log Set
AL36-L-135
Burner Assembly
AL36-CAD
Component Access Doors
AL36-HP
Hearth Plate
AL36-LKT
Light Kit
AL36-028
Fan Kit
AL36-057T
Glass Frame Assembly
700-408
Remote Control
600-002
Double Receptacle Assembly
942-085
(2) 5” Restrictor Plates