#ABY R.2 October 2020
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
INSTALLATION
27
36”
(914mm)
36”
(914mm)
Chimney must extend
3’ (914mm) above roof
Chimney must extend 2’ (210mm) above
any portion of the roof or adjacent
structures within 10’ (3.05m) of chimney
Chimney must extend 2’ (210mm) above
any portion of the roof or adjacent
structures within 10’ (3.05m) of chimney
Chimney must extend
3’ (914mm) above roof
SLANTED ROOFS
FLAT ROOFS
Figure 6.2, Chimney Locations for Roof Types
6.4 Chimney Location and Considerations
NOTE: Chimney must extend a minimum of 3' (914mm) above highest
point where it passes through roof and at least 2' (610mm) higher than
any portion of a building within 10' (3.05m).
For chimney heights and locations for slanted and flat roofs, see Figure
6.2 below.
For draft and chimney considerations, refer to Section 6.4.1 Importance
of Draft and Chimney Location on page 28.