#ABY R.2 October 2020
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
OPTIONAL FAN INSTALLATION
25
LEGEND
A
Black (hot) from incoming line
E
Ground (bare) from incoming line
B
Black from speed control
F
Ground (green) from receptacle
C
White (neutral) from incoming line
G
White from speed control
D
White (neutral) from receptacle
H
Black from receptacle
Figure 5.2, Fan Wiring and Connections
110-120 V
60 Hz
ELECTRICAL BOX
INCOMING
WIRING
SPEED CONTROL
TEMPERATURE
SWITCH
RECEPTACLE ASSEMBLY
B
A
G
H
D
F
E
C
INCOMING LINE
110-120V 60Hz
ACCESS PANEL
ROMEX CONNECTOR
ELECTRICAL BOX
RECEPTACLE / SPEED CONTROL
ASSEMBLY
Connect A to B, C to D, E to F, and G to H
GROUNDING
SCREW
GROUND
WIRE