Page 17
Yearly Maintenance
Cleaning of the suction fan and the flue tube (See pictures below)
Inspection of the grate cleaning lever
Inspection and cleaning of the air-flow sensor in aggregate test
Inspection of gaskets on the combustion chamber door and ash box
Operational test of the heat exchanger cleaning
Cleaning of the exhaust sensor
Test the igniter tube for residue
Test upper and lower parts of the burner for damage and leaks
Test the intervals of the sensors (grate motor, separator)
Lubrication of the heat exchanger cleaning drive and grate bar
Exhaust gas measurement
Cleaning of the suction fan and the flue tube
Summary of Contents for SLIMPEL
Page 8: ...Page 8 SPECIFICATIONS SLIMPEL 25...
Page 9: ...Page 9 SLIMPEL 40...
Page 10: ...Page 10 AIR ELIMINATOR VALVE BLOW OFF...
Page 14: ...Page 14 This page intentionally left blank...
Page 21: ...Page 21...