Page 1: ...SWVPC 200 100 Domestic Hot Water Cylinder With Ch Buffer Tank Assembly and operating manual ...

Page 2: ...nder s damage 8 Aconnection to water supply system must be made in accordance with legally binding norms 9 The cylinder is a pressure appliance designed for connection to the water supply system where the water pressure doesn t exceed 0 6 MPa If the water pressure exceeds 0 6 MPa the pressure reducing valve before cylinder must be fitted 10 A small leak from the safety valve through the outlet pip...

Page 3: ...ation with a central heating water pump Model SWVPC is equipped in double heating coil CW ZWEZ C PG CO ZB NW ZG CO PG PC ZG PC S Description of device Cylinder SWVPC is a device with double tank intended to heating medium system with heat pump The upper tank is enamelled with double heating coil intened to prepare domestic hot water In the lower part there is a buffer with unenamelled tank anti co...

Page 4: ...alve to the water system install the cut off valve on cold water supply pipe Hot water outlet should be led to the connections in the upper part of the cylinder Every cylinder is equipped with connection intended for its installation to the DHW circulation The buffer tank can be assembled in the heating system open system according to the current standards closed system according to the current st...

Page 5: ... Start up Before the start up make sure that the installation procedures have been carried out in accordance with the regulations included in this manual Cylinder must be filled with water turn on the valve on cold water supply pipe turn on the hot water outlet valve water outflow without the air bubbles indicates that the tank is full turn off the outlet valves Turn on the valves connecting cylin...

Page 6: ...ater hardness The cleaning should be done by a qualified person Always tighten the lid s screws to the correct torque of 18 22Nm The wear condition of the anode must be inspected annually The anode must be replaced once every 18 months anode rod replacement 3 take off upper lid 1 take out an insulation ring turn off the cut off valve on cold water supply pipe turn on the hot water valve mixer tap ...

Page 7: ... Rated temperature C 80 Surface area of heating m2 2 6 Capacity of coil dm3 14 Power of coil kW 70 22 Efficiency of coil l h 1800 550 Weight without water kg 142 Magnesium anode M8 ø40 mm 400 80 10 45 C 55 10 45 C heating water temp supply water temp domestic water temperature flowrate of heating water through the coil 2 5m3 h ...

Page 8: ...KOSPEL S A 75 136 Koszalin ul Olchowa 1 tel 48 94 31 70 565 serwis kospel pl www kospel pl ...