• Cooling:
- Type:
Off: cooling function inactive,
Fan coil,
Plane.
- Temperature of the medium: temperature of the refigerant,
- Hysteresis: Hysteresis for the refigerant.
• Cylinder:
-
Time without immersion heater: the parameter defines the time after which
the heat pump is supported it will be an additional source of heat (immersion
heater) if it does not reach the set value water temperature in the tank.
Time is counted from the moment of reaching temperature of bivalent point
[Configuration -> Heat pump -> Bivalent point]. In case the outside temperature
is above temperature of the bivalent point, the additional heat source will not
remain included. If there is a need for an additional heat, the condition for its
activation is the activation of the immersion heaters
[Configuration -> Heating
element -> use of immersion heaters: Yes]
.
- Frost protection:
Yes - activation of the storage tank frost protection in stand-by mode,
No - function inactive.
- Cylinder:
Yes - DHW tank circuit activation,
No - cylinder inactive.
•
The heat pump:
- Bivalent point: outside temperature limit to which the heat pump works
independently. Below this point, an additional heat source is activated (immersion
heater),
- Switch-off temp.: outside temperature limit at which it will be reached turning off
the heat pump. If it is necessary to heat with central heating or DHW , the only heat
source will be the immersion heater. Activation is a precondition for its activation
[Configuration -> Heating element -> use of immersion heaters: Yes]
.
•
Room temperature:
- Room control: room temperature control.
Yes - if the set temperature in the room is reached, heating on CH will be turned
off,
No - no control of exceeding the temperature in the room.
- Hysteresis: room temperature hysteresis. The parameter is available, if enabled
there is room temperature control.
• Circulation:
Yes - DHW circulation pump control system enabled,
No - DHW circulation pump system turned off.