Safety instructions
1. Read and strictly follow this installation and operating instructions to ensure
a long life and reliable boiler operation.
2. An efficient electrical installation which has been completed in accordance with
the binding.
3. Central heating system equipped with an appropriate expansion vessel completed
in accordance with binding norms of hydraulic installation.
4. Rinse the heating installation thoroughly before installing the boiler.
5. Do not install any barrier fittings (e.g. valves) on the outlet of the safety valve.
6. Boiler can only be installed on the flat surface.
7. Boiler must not be installed in a humid place, in a place exposed to the danger
of explosion, or in which the temperature may drop below 0°C.
8. Boiler must be installed in such a place and in such a way in order not to flood
the room in case of the emergency water leak.
9. Boiler must be connected to water system and central heating system in
accordance with the manufacturer's instructions. Failure to do so deprives the
user from the warranty rights and may cause device's damage.
10. Installation of the device to the water supply must be compatible with all relevant
regulations in force.
11. Maximum pressure of the hot water storage must not exceed 0,3 MPa. If system's
pressure is higher than 0,6MPa, pressure reducing valve must be fitted before
cylinder.
12. Water dripping from safety valves' down pipe is a natural occurrence and it should
not be stopped, as its blockage may lead to the device's failure.
13. It is forbidden to use the hot water storage if you suspect that safety valves may
be faulty.
14. The tank is equipped with a magnesium anode - an additional protection against
corrosion. The anode is an operating part, therefore, it is exposed to wear.
The condition of the magnesium anode should be controlled every 12 months,
however, it is due to be replaced with a new one every 18 months.
15. The boiler installation and electrical and hydraulic work must be performed by
a qualified professional installer in accordance with all instructions provided by
the manufacturer.
16. All installation work must be performed when the power and water supply are
turned off.
17. Electric installation should be equipped with residual current protective devices
and other solutions which will ensure disconnecting the heater from the source
of power (intervals between all their poles should not be less than 3 mm).
18. Do not drain the water from central heating system after the heating season.
19. Leave the controller in stand-by mode and do not cut off power supply between
the heating seasons. Proceeding otherwise may result in pump's rotor blockage.