Safety instructions

1.  Read  and  strictly  follow  this  installation  and  operating  instructions  to  ensure  

a long life and reliable boiler operation.

2.  An efficient electrical installation which has been completed in accordance with 

the binding. 

3.  Central heating system equipped with an appropriate expansion vessel completed 

in accordance with binding norms of hydraulic installation. 

4.  Rinse the heating installation thoroughly before installing the boiler.

5.  Do not install any barrier fittings (e.g. valves) on the outlet of the safety valve.

6.  Boiler can only be installed on the flat surface.

7.  Boiler must not be installed in a humid place, in a place exposed to the danger 

of explosion, or in which the temperature may drop below 0°C.

8.  Boiler must be installed in such a place and in such a way in order not to flood 

the room in case of the emergency water leak. 

9.  Boiler  must  be  connected  to  water  system  and  central  heating  system  in 

accordance with the manufacturer's instructions. Failure to do so deprives the 

user from the warranty rights and may cause device's damage. 

10.  Installation of the device to the water supply must be compatible with all relevant 

regulations in force. 

11.  Maximum pressure of the hot water storage must not exceed 0,3 MPa. If system's 

pressure is higher than 0,6MPa, pressure reducing valve must be fitted before 

cylinder.

12.  Water dripping from safety valves' down pipe is a natural occurrence and it should 

not be stopped, as its blockage may lead to the device's failure. 

13.  It is forbidden to use the hot water storage if you suspect that safety valves may 

be faulty. 

14.  The tank is equipped with a magnesium anode - an additional protection against 

corrosion. The  anode  is  an  operating  part,  therefore,  it  is  exposed  to  wear. 

The condition of the magnesium anode should be controlled every 12 months, 

however, it is due to be replaced with a new one every 18 months.

15.  The boiler installation and electrical and hydraulic work must be performed by 

a qualified professional installer in accordance with all instructions provided by 

the manufacturer. 

16.  All installation work must be performed when the power and water supply are 

turned off.

17.  Electric installation should be equipped with residual current protective devices 

and other solutions which will ensure disconnecting the heater from the source 

of power (intervals between all their poles should not be less than 3 mm).

18.  Do not drain the water from central heating system after the heating season.

19.  Leave the controller in stand-by mode and do not cut off power supply between 

the heating seasons. Proceeding otherwise may result in pump's rotor blockage. 

Summary of Contents for EKD.M3

Page 1: ...Bi functional Electric Central Heating Flow Boiler EKD M3 Assembly and operating instructions...

Page 2: ...get more detailed information about recycling this product you should contact the local government unit waste management service or the shop where this product has been purchased This appliance is not...

Page 3: ...water storage must not exceed 0 3 MPa If system s pressure is higher than 0 6MPa pressure reducing valve must be fitted before cylinder 12 Water dripping from safety valves down pipe is a natural occu...

Page 4: ...ll safety armature Temperature of heating medium supply and return Capacity of central heating system Pressure in central heating system C l bar 85 70 116 1 5 70 55 158 55 45 206 50 40 230 45 35 256 1...

Page 5: ...onnection whereas the circuit pump has to be connected to CYRK clasp on the terminal block 8 Extend the pipes placed on the back wall of the device responsible for safety valve s leak and locate them...

Page 6: ...or boilers of 4kW 6kW and 8kW PNL connection points of neutral protective and phase conductors 1 temperature limiter 2 additional conductors for single phase system only FUN MA RT Tcyl Tos Tr M SUPPLY...

Page 7: ...boiler s work to the mode of maintaining the temperature previously set in the configuration menu Configuration FUN entry Room thermostat entry RT This optional entry is responsible for boiler s contr...

Page 8: ...ondition of the anode must be inspected annually The anode must be replaced once every 18 months Heat up the water above 70 C periodically for hygiene reasons Failures or malfunctions notify to the ma...

Page 9: ...protective conductor from the bottom and upper lid Undo two screws holding upper lid 3 4 and take the lid out by tilting it towards the back 5 Turn off the cut off valve on cold water supply pipe tur...

Page 10: ...ply cable circulation heating medium supply heating medium return 1 expansion vessel DHW 2 expansion vessel CH 3 pump CH 4 power board 5 safety valve CH 3bar 6 safety valve DHW 6bar 7 anode 8 electric...

Page 11: ...ice configuration allows configuration of the system heating to the conditions of the facility available for specialized services and preview of boiler s input and output signals party holiday manual...

Page 12: ...e TURBO heating up the maximum parameters until the set room temperature is reached Implementation of the frost protection program Storage disinfection Circulation pump venting Temperature settings fo...

Page 13: ...rames which can have one of the roomtemperaturesets In any other case the economic temperature will be activated Setting up daily programs procedure is described in Daily Schedule paragraph Weekly ass...

Page 14: ...ot water is heated in order to achieve the best possible energy efficiency class in accordance with the terms of the ErP Directive Individual customized to user s needs switching time and water temper...

Page 15: ...ow start disinfection manually irrespective of a day and time set previously DATE TIME setting current system time year month day of the month and day of the week hour INTERFACE Brightness MIN setting...

Page 16: ...of input and output signals of the boiler Configuration adaptation of the boiler to the heating system in the facility Changes in the configuration menu are possible after entering an access code Whe...

Page 17: ...on and re entering MENU items select settings of the remaining parameters TURBO ROOM TEMP HYSTERESIS room temperature fall triggers this function HOT WATER TANK No turns off hot water for the Turbo fu...

Page 18: ...mains service speed transmission speed on the mains INLET FUN selection of reaction to closing FUN inlet either setting economy temperature or frost protection PRESSURE CONTROL no switching the contr...

Page 19: ...ing edition of next parameters Last editable time position is a command To confim changes use the dial to select a command accept and press the dial to finish editing To delete time settings edit a gi...

Page 20: ...ired temperature is reached in a room This function can start automatically when room s temperature falls down by the set room temperature hysteresis Automatic work is set in menu CONFIGURATION TURBO...

Page 21: ...in the installation Correlation between outside temperature and heating installation s temperature can be presented in a graphical form of so called heating curve The diagram below presents a compilat...

Page 22: ...Pa 150 Bypass valve kPa Adjustable 10 50 Safety valve MPa Opening pressure 0 3 Boiler s connections G 3 4 inside thread DOMESTIC HOT WATER CYLINDER Surface area of coil m2 1 Power of coil in temp 85 6...

Page 23: ...storage 15 C 55 C min 107 72 54 107 72 54 EKD M3 BOILER 12 16 20 24 Rated power kW 12 16 20 24 Rated voltage 400V 3N Rated current A 3x17 4 3x23 1 3x28 8 3x34 6 Min connecting wires section mm2 5 x 2...

Page 24: ...KOSPEL S A 75 136 Koszalin ul Olchowa 1 tel 48 94 31 70 565 serwis kospel pl www kospel pl...

Reviews: