24
34
Fig.34 Extended Menu
To change parameters press
or
. To save your changes press
.
Push- buttons specification:
– return to the main view
– save changes
– not applicable
Instruction for the user
The code let you go to
„
Extended Menu
”
page as shown in fig.34
Important: The boiler doesn’t operate while the parameters are being changed.
– not applicable
– to increase the value
– to decrease the value
Heating parameters
fig. 3a or fig.4
- for radiator
central heat-
ing system
fig.3b – for
under-floor
heating
system
Tco0
CH medium temperature in the case of outdoor temperature sensor failure
70
50
IKEYt
time (sec.) the
„
Main View
”
page automatically returns if you don’t use any buttons
This parameter is not applicable for
„
Extended Menu
”
page
30
30
Tcomax
maximum CH medium temperature in the central heating system
85
60
3F_e
1 indicates the symmetry failure , 0 indicates that there is no symmetry failure. Parameter
value is 0 for single-phase boilers.
zew_t
outdoor temperature reading intervals (min.) . 0 indicates the reading for every sec. 1 indicates
the reading for every minute
10
10
pok_t
room temperature reading intervals (min.) . 0 indicates the reading for every sec. 1 indicates
the reading for every minute
5
5
ZG_MOC
power of the heating box
NS
number of heating elements
6
6
WChG
radiator coefficient
Grz.
Pod.
Grz.
main circuit (radiator)
Nag.
main circuit (heater)
Pod.
main circuit (under-floor heating)
Tcomin
minimum CH medium temperature in the central heating system.
29
29
PZMR
desired room temperature for antifreeze program
7
7
Nr
number of slave boiler in cascade connection
0
0
code1,
code2,
code3
three digit code to enter
„
Extended Menu
”
.
Tcwu
outlet boiler temperature (DHW heating)
85
85
Tzas
parameter of the following value:
styk
if you use cylinder thermostat
DS.
if you apply Kospel temperature sensor
Tzas_h
DHW Cylinder hysteresis (Celcious degree)
10
10
Tc2max
maximum heating temperature of the second circuit
60
-