![Kospel 5906564170430 Manual Download Page 23](http://html1.mh-extra.com/html/kospel/5906564170430/5906564170430_manual_1999259023.webp)
PL;DE;GB;FR,RU-057ABC_f.976
23
EPME water heater
5,5 6,0 6,5 7,0 7,5 8,0 8,5 9,0
Rated power
kW 5,5
6,0
6,5
7,0
7,5
8
-
-
Rated voltage
220V ~
Rated current
A 25,0 27,3 29,6 31,9 34,2 35,4
-
-
Min. connecting wires
section
mm
2
3 x 6
Efficiency (at Δt = 40°C)
l/min 2,0
2,2
2,3
2,5
2,7
2,9
3,1
3,2
Max. connecting wires
section
mm
2
3 x 16
Pressure in the water mains MPa
0,1 ÷ 0,6
Activation point
(min. rate of flow)
l/min
2,0
Temperature adjustment
range
°C
30 ÷ 60
Overall dimension
(height x width x depth)
mm
350 x 200 x 110
Weight
kg
~3,3
Water fittings
G 1/2”
Rated power
kW 5,5
6,0
6,5
7,0
7,5
8,0
8,5
9,0
Rated voltage
240V ~
Rated current
A 22,9 25,0 27,0 29,2 31,3 33,3 35,5 37,6
Min. connecting wires
section
mm
2
3 x 6
Rated power
kW 5,5
6,0
6,5
7,0
7,5
8,0
8,5
-
Rated voltage
230V ~
Rated current
A 23,9 26,1 28,3 30,4 32,6 34,8 37,0
-
Min. connecting wires
section
mm
2
3 x 6
Technical data
GB
Summary of Contents for 5906564170430