20
Before you supply voltage for the first time, make sure that
you set the heater’s power at appropriate value (always
consider the capacity of your home’s electrical system).
A power configuration shall be performed by authorized
person (installer or service engineer) Set the switches 1-3
at appropriate position to configure the heater.
Switch number 4 at ON position blocks access to the
heater’s setting. In this case, the display shows the
desired temperature value (which has been adjusted
before the heater start-up), the heating icon and other
possible working characteristics. When you supply
voltage to the heater the display will show (PW...)- the
control panel software version, (MSP....)- the controller
software version and the power value that has been set.
8,5kW
8,0kW
7,5kW
7,0kW
6,5kW
6,0kW
5,5kW
P
P
P
P
P
P
P
9,0kW
P
The heater switches on automatically straight after
reaching the flow rate over 2,0 l/min. The temperature
control system adjusts the power rate according to
the water flow rate, required temperature and the
temperature of water in the mains. The LCD backlight
and icon signalises the heating operation. If the unit
reach the maximum power value which is too low for
a given operating conditions the LCD display will show
flickering icon. The LED display backlight also turns on
while pushing or turning the setting knob. The backlight
will automatically turn off when the heating operation
is turned off, or if more than 50 seconds have passed
since the last adjustment.
If you block the unit by master appliance (NA entry) the
display will show „NA BLOCK”.
electronic
ATTENTION!
-
for power supply of 220V maximum rated
power is 7,8kW [for the setting 8,0]
-
for power supply of 230V maximum rated
power is 8,5kW
Configuration
Operation
Summary of Contents for 5906564170430
Page 31: ...PL DE GB FR RU 057ABC_f 976 31 1 2 3 EPME 4 5 6 7 8 9 10 11 0 C 12 13 14 RU...
Page 32: ...32 1 2 3 4 5 6 7 2 8...
Page 33: ...PL DE GB FR RU 057ABC_f 976 33 1 2 p py o 15 30 3 4...
Page 35: ...PL DE GB FR RU 057ABC_f 976 35 50 NA NA O T BX O T MAKC O T MAKC LCD ECO 3 10 5 T MO 10...
Page 39: ......