- 12 -
ance switches on at speed level 1, If the cooker hood is
on depress the push-button for 2 sec. to switch off the
cooker hood. If the cooker hood is at speed level 1 it will
not be necessary to depress the push-button to switch
the cooker hood off. Decreases the motor speed.
Display C
= indicates the motor speed level selected
and activates the timer.
Push-button D
= switches on the cooker hood. In-
creases the motor speed. Touching the key at 3rd speed,
the intensive function runs for 10', then the appliance go
back to work at the original speed. During this function
the display blinks.
Key E
= The Timer times the functions on activation for
15 minutes, after which they are switched off. The Timer
is deactivated by re-pressing
Key E
. When the Timer is
activated the decimal point must flash on the display.
The Timer cannot be activated if the intensive speed is
functioning.
The
“clean air”
function is activated by pressing key
E
for 2 seconds when the appliance is switched off. This
switches the motor on for 10 minutes every hour at the
first speed. During functioning a rotary movement of the
peripheral segments must be visualised on the display.
When this time has passed the motor switches off and
the fixed letter
“C”
must be visualised on the display
until the motor re-starts after 50 minutes for another 10
minutes and so on. Press any key apart from the light
keys to return to normal functioning. Press key
E
to
deactivate the function.
• Active carbon/grease filter saturation:
- When display item
C
flashes, at a speed where it
alternates with the letter
F
(e.g. 1 and
F
), the
grease
filters must be washed.
- When display item
C
flashes, at a speed where it
alternates with the letter
A
(e.g. 1 and
A
), the
carbon
filters must be replaced.
After the clean filter has been positioned correctly, the
electronic memory must be reset by pressing button
A
for approximately
5 seconds
, until the indication
F
or
A
shown on the display
C
stops flashing.
• COMMANDS: ELECTRONIC
(Fig.22A):
A
= LIGHT
B
= OFF/SPEED I
C
= SPEED II
D
= SPEED III
E
= AUTOMATIC STOP TIMER – 15 minutes
(*)
F
= FILTER SATURATION RESET LIGHT
When the “filter saturation” light flashes, the anti-grease
filters must be washed. When the light comes on without
flashing, the anti-grease filters must be washed and the
carbon filters replaced (in case of operation whit the re-
cycling version). When this operation has been com-
pleted, press the key to reset it.
• COMMANDS:
(Fig.23)
LUMINOUS
- (Fig.22B)
ELECTRONIC
the key
symbols are explained below:
A
= LIGHT
B
= OFF
C
= SPEED I
D
= SPEED II
E
= SPEED III
F
= AUTOMATIC STOP TIMER - 15 minutes
(*)
•
If your appliance does not have the
INTENSIVE
speed
function, press key E for two seconds and it will be
activated for 10 minutes after which it will return to the
previously set speed. When the function is active the LED
flashes. To interrupt it before the 10 minutes have expired
press key
E
again.
•
By pressing key
F
for two seconds (with the hood
switched off) the “
clean air
” function is activated. This
function switches the appliance on for ten minutes every
hour at the first speed. As soon as this function is acti-
vated the motor starts up at the first speed for ten
minutes, During this time key
F
and key
C
must flash at
the same time.
After ten minutes the motor switches off and the LED of
key
F
remains switched on with a fixed light until the
motor starts up again at the first speed after fifty min-
utes and keys
F
and
C
start to flash again for ten min-
utes and so on.
By pressing any key for the exclusion of the hood light
the hood will return immediately to its normal functioning
(e.g. if key D is pressed the “
clean air
” function is deac-
tivated and the motor moves to the 2nd speed straight
away. By pressing key
B
the function is deactivated).
(*)
The
“automatic stop timer”
delays stopping of the
hood, which will continue functioning for 15 minutes at
the operating speed set at the time this function is
activated.
• Active carbon/grease filter saturation:
- When button
A
flashes at a frequency of
2 seconds
,
the
grease
filters must be cleaned.
- When button
A
flashes at a frequency of
0.5 seconds
,
the
carbon
filters must be replaced.
After the clean filter has been replaced, the electronic
memor y m ust be reset by pressing button
A
for
approximately
5 seconds
, until the light on the button
stops flashing.
•COMMANDS:
(Fig.24A)MECHANICAL_(Fig.24B) Elliptic
the key symbols are explained below:
A
= LIGHT
B
= OFF
C
= SPEED I
D
= SPEED II
E
= SPEED III
G
= MOTOR WORKING indicator
THE MANUFACTURER DECLINES ALL
RESPONSIBILITY FOR EVENTUAL DAMAGES
CAUSED BY BREACHING THE ABOVE WARNINGS.
Summary of Contents for KHA 7950 X Cube
Page 1: ......
Page 3: ...3 M max 80 cm X A B D D D L 2 A 2 B Fig 1 A B C Fig 2 Fig 3...
Page 4: ...4 B C D D M E D B C D E Fig 4 Fig 5...
Page 5: ...5 B C G B C G D D B C X X E G Fig 6 Fig 7 Fig 8...
Page 6: ...6 Max 3 mm N N O O O M 11A 11B 11C N O 11D N Fig 9 Fig 11 Fig 10...
Page 7: ...7 E H H F D D L Fig 12 Fig 13 Fig 14...
Page 8: ...8 Y Y N Y Y A B C Fig 15 Fig 16 Fig 17...
Page 37: ...37 RUS 1 1 1C 1 4Pa 4x10 5 bar 2 A B C D E F G H I 2002 96 WEEE II L N c 3 c 65 19 150 17...
Page 43: ...3LIK0341...