4
If the “Exclusive” (GLOBAL 2.1–1b) setting is checked,
MIDI exclusive parameter changes will be transmitted
whenever you operate the Performance Editor. If these
messages are received by a TRITON-Rack whose
“Exclusive” setting is checked, the Performance Editor
corresponding to that message will be modified.
Octave
[–03...+00...+03]
An adjustment of +01 will raise the pitch one octave.
An adjustment of –01 will lower the pitch one octave.
This setting cannot adjust the pitch higher than 4' (feet) or
lower than 32' (feet).
Stretch (Pitch Stretch)
[–12...+00...+12]
This simultaneously adjusts the Transpose and Tune of the
oscillator. This lets you produce a variety of tonal changes
and variations without loosing the character of the original
sound.
At the +00 setting, the value of the program parameters will
be unchanged.
An adjustment of +01 will lower the Transpose value by 1,
and simultaneously raise the Tune value by 100.
An adjustment of –01 will raise the Transpose value by 1,
and simultaneously lower the Tune value by 100.
However, it is not possible for the Transpose value to exceed
the range of
±
12, nor the Tune value to exceed the range of
±
1200.
This Performance Edit function cannot be used for
bank I–F
.
OSC Bal (OSC Balance)
[–10…+00…+10]
This adjusts the level balance between oscillators 1 and 2.
At the +00 setting, the value of the program parameters will
be unchanged.
Positive (+)
settings will lower the oscillator 2 level.
With an adjustment of +10, the oscillator 2 level will be 0.
The oscillator 1 level will not change.
Negative (–)
settings will lower the oscillator 1 level.
With an adjustment of –10, the oscillator 1 level will be 0.
The oscillator 2 level will not change.
For programs whose “Mode (Oscillator Mode)” (2.1–1a)
setting is Single, oscillator 2 will not sound. Only the
level of oscillator 1 will change. For a Drums program,
this performance editor will have no effect.
Level (Amp Level)
[–10…+00…+10]
This adjusts the amp level.
With an adjustment of +00, the value of the program param-
eters will be unchanged.
Positive (+)
settings will increase the amp level above the
value that was set.
With an adjustment of +10, the amp level will be 127 (maxi-
mum).
Negative (–)
settings will lower the amp level below the
value that was set.
With an adjustment of –10, the amp level will be 0.
Attack (Attack Time)
[–10…+00…+10]
This adjusts the attack times of the filter EG and amp EG.
With an adjustment of +00, the value of the program param-
eters will be unchanged.
Positive (+)
settings will lengthen the attack times beyond
the values that were set.
With an adjustment of +10, the attack times will be 90.
Negative (–)
settings will shorten the attack times.
With an adjustment of –10, the attack times will be 0.
When you modify “Attack Time,” the EG Start Level,
Attack Level, Start Level Modulation, and Attack Time
Modulation of the amp EG will also be adjusted simul-
taneously, to allow the maximum effect to be obtained.
Decay (Decay Time)
[–10…+00…+10]
This adjusts the Decay Time and Slope Time of the filter EG
and amp EG.
With an adjustment of +00, the value of the program param-
eters will be unchanged.
Positive (+)
settings will lengthen the Decay Time and Slope
Time beyond the values that were set. With an adjustment of
+10
, the times will be 99.
Negative (–)
settings will shorten the Decay Time and Slope
Time. With an adjustment of –10, the times will be 0.
IFX Bal (IFX Balance)
[–10…+00…+10]
This adjusts the “W/D(Wet/Dry)” setting of insertion
effects 1–5 as a whole.
With an adjustment of +00, the value of the program param-
eters will be unchanged.
Positive (+)
settings will raise the Wet levels above the pro-
gram setting, and lower the Dry levels. With an adjustment
of +10, the setting will be “Wet.”
Negative (–)
settings will lower the Wet levels below the
program setting, and raise the Dry levels. With an adjust-
ment of –10, the setting will be “Dry.”
MFX Bal (MFX Balance)
[–10…+00…+10]
This adjusts the master effect “Rtn1 (Return1)” and “Rtn2
(Return2)” (7.3–1a) settings as a whole.
With an adjustment of +00, the value of the program param-
eters will be unchanged.
Positive (+)
settings will raise the return levels above the
program setting.
With an adjustment of +10, the setting will be 127 (maxi-
mum).
Negative (–)
settings will lower the return levels below the
program setting.
With an adjustment of –10, the setting will be 0.
For the bank I–F programs that can be used when the
separately sold EXB-MOSS option is installed, different
program parameters will be adjusted.
(
☞
EXB-MOSS owner’s manual & p.251 “EXB-MOSS
option”)
■
1.1–2c: UTILITY
☞
“Write Program,” “Select by Category” (1.1–1d)
Octave
Octave of OSC 1 and 2
Stretch
Transpose and Tune of OSC 1 and 2
OSC Bal
High Level and Low Level of OSC1 and 2
Level
Amp1 Level, Amp2 Level
Attack
Amp EG Attack Time, Start Level, Attack Level,
Level Modulation St, Time Modulation At of Amp 1
and 2, and Filter EG Attack Time of Filter 1 and 2
Decay
AmpEG Decay Time, Slope Time of Amp 1 and 2,
Filter EG Decay Time and Slope Time of Filter 1
and 2
IFX Bal
W/D(Wet/Dry) balance of the IFX1/2/3/4/5 effects
MFX Bal
Master Effect RTN1, 2(Return1, 2)