![Korg KingKORG Service Manual Download Page 17](http://html1.mh-extra.com/html/korg/kingkorg/kingkorg_service-manual_1998540017.webp)
The main display is displayed as shown in the picture
shown to the right.
Check the voltage with a digital multimeter.
The following table shows the standard voltage.
Lower limit
Reference value
Upper limit
Unit
0.990
1.000
1.010
V
After confirming, press the [VALUE dial], proceed to the next inspection
Connect to the GATE terminal of the multimeter to V of CV/GATE testing cable.
The main display is displayed as shown in the picture
shown to the right.
Check the voltage with a digital multimeter.
The following table shows the standard voltage.
Lower limit
Reference value
Upper limit
Unit
0.000
0.000
0.500
V
After confirming, press the [VALUE dial], proceed to the next inspection.
The main display is displayed as shown in the picture
shown to the right.
Check the voltage with a digital
multimeter.
The following table shows the standard voltage.
Lower limit
Reference value
Upper limit
Unit
4.500
5.000
5.500
V
After confirming, press the [VALUE dial], proceed to the next inspection
Connect to the GATE terminal of the multimeter to V of CV/GATE testing cable.
4. LED and display check
4-1. Display and L ED all lights check
The main display and the L ED will illuminate all as shown in the photo below and next page.