background image

Installation 

    
1.Install the mobile air conditioner in a flat  
    and spacious location where the air outlets 
    will not be obstructed. 
2.A minimum clearance of 50cm from walls 
    or other obstacles should be kept. 

Note:

 1.The air conditioner shall not be 

               used in the laundry.
           2.The plug shall be accessible after
               the unit is positioned. 

   

  

   

Accessories 

Parts

Parts name 

Quantity

Duct 

Adaptor

 Windows installation board

Alkaline batteries 

Remote controller 

1

1

2

1

     

The customer should have a qualified power supply coincident with that 

   printed on the tag of the air conditioner. Its voltage should be in the range 
   of 90%-110% of its rated voltage. 

Must use special circuit and efficient grounding outlet matching with 

   the plug of the air conditioner.

If the supply cord is damaged, it must be replaced by the manufacturer, 

   its service agent or similarly qualified persons in order to avoid a hazard.  

7

4

More than

 50cm 

1

   

 Deal with water condensate 

When the inside water tank is full, the water 
full display is lighted.
1. Open the drain cover  and extract it upwards. 
2.put one container or drain cover under the drain
   pipe, take off the plug on the drain pipe and let 
   out the condensing water.
3.after let out all the condensing water, put the 
   plug back onto the drainage outlet, then cover 
   the drain cover.

IMPORTANT: 

This water is not suitable for

                             drinking.

Select a best location 

Guide of customer 

bolt

1

nut

1

Down drain outlet

M

or

th

an

 5

0c

m

 

NOTE:
This remote control  is the general type, so some  functions such as SWING,
HEALTH,HUMIDITY,and FEELING  are  not  avaiable  for  this  unit.

Summary of Contents for KMA1-12GRC

Page 1: ...PORTABLE AIR CONDITIONER INSTALLATION OPERATIONS MANUAL FOR FUTURE REFERENCE KMA1 12GRC KOREL AIR CONDITIONING...

Page 2: ...Wiring diagram HEATER ONLYTHE UNIT WITH HEATING MODE HAS HEATER Cooling Heating 12...

Page 3: ...ambient temperature Clean the airfilter Remove the obstruction Allow additional time to remove stored heat from walls ceiling floor and furniture Reconfirm the required cooling capacity with yourdeal...

Page 4: ...ons below to see if you can solve your problem without outside help Causes Solutions The power switch is released Power supply failure The fuse is burnt It doesn t reach the set time for start up Swit...

Page 5: ...er is designed to give you many years of dependable service This section tells you how to clean and care for your air conditioner properly Window kit installation Your window kit has been design to fi...

Page 6: ...itioner According fix it with unit correspondingly then turn right Push it downwards make sure thatit is fixed thoroughly 2 Put theother side ofthe duct to adaptor 3 Put the adapor to a nearby window...

Page 7: ...let matching with the plug of the air conditioner If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 7 4...

Page 8: ...ain to stop 5 6 Operation Failure to follow the below precaution could result in electrical shock fire or personal injury 1 The plug must be plugged into an outlet that is properly installed and groun...

Reviews: