background image

Parts Description 

Note:

 

1.The duct can be compressed to 450mm minimum and extended to 

              1800mm maximum. It is better to keep the duct length to a minimum.
           2.Stretching or bending the duct excessively will affect the cooling 
               efficiency.
             

3

8

Do not!

1. Put one side of duct to the 
    exhaust air outlet of mobile air 
    conditioner, According fix it 
    with unit correspondingly, then 
    turn right, Push it downwards, 
    make sure that it is fixed 
    thoroughly.

2. Put the other side of the duct
    to adaptor.

3. Put the adapor  
  to a  nearby window. 

Adaptor

Duct mount instruction 

 (

As the following fig. Show) 

Front panel 

Control panel 

 Air outlet 

Truckle  

  Handle recess

FRONT VIEW 

Remote controller 

REAR VIEW 

Down drain outlet 

Up drain outlet 

Air intake(condenser) 

Exhaust air outlet 

Air inlet 

Rear panel 

Air filter (inside)

Filter cover

Drain cover board

1

2

Yes!

Summary of Contents for KMA1-12GRC

Page 1: ...PORTABLE AIR CONDITIONER INSTALLATION OPERATIONS MANUAL FOR FUTURE REFERENCE KMA1 12GRC KOREL AIR CONDITIONING...

Page 2: ...Wiring diagram HEATER ONLYTHE UNIT WITH HEATING MODE HAS HEATER Cooling Heating 12...

Page 3: ...ambient temperature Clean the airfilter Remove the obstruction Allow additional time to remove stored heat from walls ceiling floor and furniture Reconfirm the required cooling capacity with yourdeal...

Page 4: ...ons below to see if you can solve your problem without outside help Causes Solutions The power switch is released Power supply failure The fuse is burnt It doesn t reach the set time for start up Swit...

Page 5: ...er is designed to give you many years of dependable service This section tells you how to clean and care for your air conditioner properly Window kit installation Your window kit has been design to fi...

Page 6: ...itioner According fix it with unit correspondingly then turn right Push it downwards make sure thatit is fixed thoroughly 2 Put theother side ofthe duct to adaptor 3 Put the adapor to a nearby window...

Page 7: ...let matching with the plug of the air conditioner If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 7 4...

Page 8: ...ain to stop 5 6 Operation Failure to follow the below precaution could result in electrical shock fire or personal injury 1 The plug must be plugged into an outlet that is properly installed and groun...

Reviews: