KORADO RE10A Operating Instructions Manual Download Page 6

marked with the small     symbol, the highest in the position marked with the large     symbol. Temperature is 
regulated within the range 5°- 30°C according to the position of the control dial.
Operation of the appliance is ended by switching off the      switch.

Drying programme

The regulator is first set into drying mode using the         switch. If the user requires activation of the drying 

programme, he/she must press the      button, which activates the drying programme. The orange indicator light 
will light up and the electric heating element will work at full power for a period of two hours. After this period has 
ended, the regulator will switch back to heating mode. If the user wishes to end the drying programme earlier, 
pressing the       button again ends the drying programme and the regulator will switch to heating mode.

Operational indication – indicator light status

Green 

– 

the equipment is switched on, it is not heating, the temperature in the room is higher 
than the temperature set on the regulator

Red

 the equipment is in operation, heating in heating mode

Orange 

– 

the equipment is in operation, heating in drying mode

Unlit

 

– 

the regulator is switched off

Flashing

 

(2-5  red  flashes  once  every  minute)  –  error  status. The  manufacturer  recommends 
switching off the equipment for a period of 1 minute and then restarting. If the equipment 
does not start up, a service technician must be called in.

Any possible repairs to the regulator may only be performed by the manufacturer or a specialist electrical 

repair  centre.  The  regulator  is  manufactured  in  accordance  with  ÈSN  EN  60  335-1  “Safety  of  electrical 
appliances for household and similar purposes”. The RE10A electronic temperature regulator was tested and 
certified in the Electrotechnical Testing Institute in Prague.

Technical data

Temperature regulation range 

5°- 30°C

Nominal voltage 

 

230V/50Hz

Protection 

IP 20

Max. switched current

10 A

Electrical class

I

Drying programme duration

2 hours

Fig. 3                                  

Fig. 4

Safety instructions

If water gets into the plug, you must not plug it into the socket! Have it repaired by a specialist.

The  RE10A  electric  regulator  is  not  designed  for  use  by  people  (including  children)  whose 
physical, sensory or mental disability or lack of experience and knowledge, prevents them from 
using it safely unless supervised or instructed with regards to use of the appliance by the person 
responsible for their safety.

Children must not be left to play unsupervised with the electric regulator.

Method of removing
the regulator housing

U - 

live conductor

      (black or brown)

N - zero conductor
     (blue)


  (green/yellow)

guard conductor

 

Connection of
the cable to the
connection block
with U, N and  
markings

 

E

N

G

L

IS

H

Summary of Contents for RE10A

Page 1: ...ectronique Elektryczny regulator temperatury N VOD K POU IT OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG MODE D EMPLOI INSTRUKCJA U YTKOWANIA KORADO a s B Hub lk 869 560 02 esk T ebov Info linka zdarma...

Page 2: ...e tak aby kabelov v vod z regul toru vystupoval v dy dole viz Obr 2 Jin pracovn poloha regul toru nen p pustn Elektronick regul tor teploty RE10A nesm b t v prostoru koupelny um st n v z n ch 0 1 a 2...

Page 3: ...zpe nostn pokyny Pokud do vidlice vnikla voda je zak z no j zasouvat do z suvky Zajist te jej odbornou opravu Elektronick regul tor RE10A nen ur en pro pou v n osobami v etn d t jim fyzick smyslov neb...

Page 4: ...ESKY...

Page 5: ...qualifications pursuant to Decree no 50 78 Coll When fitting is performed outside of the Czech Republic the corresponding national regulations must be adhered to The regulator must always be positione...

Page 6: ...ends switching off the equipment for a period of 1 minute and then restarting If the equipment does not start up a service technician must be called in Any possible repairs to the regulator may only b...

Page 7: ...e to the instructions for mounting and operation as set out in these operating instructions The product must always be sent with the guarantee certificate for guarantee repairs An accompanying letter...

Page 8: ...an die der Regler angeschlossen wird Die Kontrolle der Netzsteckdose und die Montage des Reglers darf lediglich eine Person mit der entsprechenden elektrotechnischen Qualifikation gem Verordnung Nr 5...

Page 9: ...eses durch erneutes Dr cken derTaste und der Regler geht in den Heizmodus ber Betriebsanzeigen Zustand der Signalleuchte Gr n die Anlage ist eingeschalten sie heizt nicht im Raum herrscht eine h here...

Page 10: ...rt daf r dass das Produkt ber die gesamte Garantiezeit die durch die entsprechenden Normen festgelegten Eigenschaften unter der Voraussetzung haben wird dass es auf die Art und Weise montiert und genu...

Page 11: ...raccord Le contr le de la prise r seau et le montage du r gulateur ne peuvent effectu s que par une personne ayant des comp tences lectrotechniques suffisantes r pondant aux dispositions de l Arr t n...

Page 12: ...e ce qui entra ne l arr t du programme de s chage Le r gulateur repassera alors automatiquement en mode de chauffage Indications tat du voyant Vert l quipement est install il ne chauffe pas la temp ra...

Page 13: ...au long de la p riode de garantie le produit aura les propri t s fix es par les normes techniques applicables condition qu il soit mont et utilis de la mani re d crite dans le pr sent mode d emploi L...

Page 14: ...fachowo sprawdzi gniazdko sieciowe z kt rym regulator b dzie wsp pracowa Kontrol gniazdka i monta regulatora mo e wykona wy cznie osoba posiadaj ca wymagane kwalifikacje i uprawnienia w zakresie elek...

Page 15: ...ie regulatora do trybu grzania Sygnalizacja podczas pracy stan lampki sygnalizacyjnej Zielona urz dzenie jest w czone nie grzeje w pomieszczeniu panuje wy sza temperatura ni jest ustawiona na regulato...

Page 16: ...lektronicznym Gwarancja Producent gwarantuje e wyr b przez ca y okres gwarancji b dzie odznacza si w a ciwo ciami okre lonymi w odpowiednich normach technicznych pod warunkiem e zostanie zamontowany i...

Page 17: ...RE10A RE10A KORADO a s KORALUX RADIK COMBI VK KORALUX E 5 2 RE10A 0 1 2 SN 33 2000 7 701 1 1 2 3 U N 4 U N 0 2 1 2 2 50 0 6 0 600 600...

Page 18: ...230V 50Hz 5 30 C 2 2 5 1 SN EN 60 335 1 RE10A 5 30 C 230V 50Hz IP20 10A I 2 3 4 U N U N...

Page 19: ...RE10A...

Page 20: ...ndu le Sprzedano dnia Raz tko a podpis prod vaj c ho Dealer s stamp and signature Stempel und Unterschrift des Verk ufers Cachet et signature du vendeur Piecz tka i podpis sprzedaj cego Bez data prode...

Reviews: