marked with the small symbol, the highest in the position marked with the large symbol. Temperature is
regulated within the range 5°- 30°C according to the position of the control dial.
Operation of the appliance is ended by switching off the switch.
Drying programme
The regulator is first set into drying mode using the switch. If the user requires activation of the drying
programme, he/she must press the button, which activates the drying programme. The orange indicator light
will light up and the electric heating element will work at full power for a period of two hours. After this period has
ended, the regulator will switch back to heating mode. If the user wishes to end the drying programme earlier,
pressing the button again ends the drying programme and the regulator will switch to heating mode.
Operational indication – indicator light status
Green
–
the equipment is switched on, it is not heating, the temperature in the room is higher
than the temperature set on the regulator
Red
–
the equipment is in operation, heating in heating mode
Orange
–
the equipment is in operation, heating in drying mode
Unlit
–
the regulator is switched off
Flashing
–
(2-5 red flashes once every minute) – error status. The manufacturer recommends
switching off the equipment for a period of 1 minute and then restarting. If the equipment
does not start up, a service technician must be called in.
Any possible repairs to the regulator may only be performed by the manufacturer or a specialist electrical
repair centre. The regulator is manufactured in accordance with ÈSN EN 60 335-1 “Safety of electrical
appliances for household and similar purposes”. The RE10A electronic temperature regulator was tested and
certified in the Electrotechnical Testing Institute in Prague.
Technical data
Temperature regulation range
5°- 30°C
Nominal voltage
230V/50Hz
Protection
IP 20
Max. switched current
10 A
Electrical class
I
Drying programme duration
2 hours
Fig. 3
Fig. 4
Safety instructions
-
If water gets into the plug, you must not plug it into the socket! Have it repaired by a specialist.
-
The RE10A electric regulator is not designed for use by people (including children) whose
physical, sensory or mental disability or lack of experience and knowledge, prevents them from
using it safely unless supervised or instructed with regards to use of the appliance by the person
responsible for their safety.
-
Children must not be left to play unsupervised with the electric regulator.
Method of removing
the regulator housing
U -
live conductor
(black or brown)
N - zero conductor
(blue)
-
(green/yellow)
guard conductor
Connection of
the cable to the
connection block
with U, N and
markings
E
N
G
L
IS
H