BAKL40T12AE
Edition: 20.04.2009
Page: 9/12
4.4.1. Manuel adjustment of the evaporator performance
By pressing key S4 the required air volume can be adjusted manual. (LED lights up)
Changing the setting/display with key S4:
Display shows:
0
= automatic blower regulation
Display shows:
1
= Manual SLOW
Display shows:
2
= Manual MIDDLE
Display shows:
3
= Manual FAST
4.5.
4.5.
4.5.
4.5.
Recirculated air operation
Recirculated air operation
Recirculated air operation
Recirculated air operation
Starting of the recirculated air operation:
Starting of the recirculated air operation:
Starting of the recirculated air operation:
Starting of the recirculated air operation: Press key S5, LED lights up.
In recirculated air operating mode, the flow of external air in the vehicle‘s passenger compartment is blocked and the
system recirculates the air existing in the vehicle‘s interior. This keeps the vehicle‘s environment uncontaminated from
polluted air that might be sucked from the outside (e.g. in tunnels).
This position should not be adjusted very long. If windows are misting up, return air operation should be
switched off immediately by pressing key S5 (LED goes out
goes out
goes out
goes out).
4.6.
4.6.
4.6.
4.6.
Blinking code in display
Blinking code in display
Blinking code in display
Blinking code in display
If there is no feedback signal from the low- or high pressure switch at the compressor the decimal point in
the display is blinking
⇒
⇒
⇒
⇒
immediately contact one of the
KONVEKTA
KONVEKTA
KONVEKTA
KONVEKTA
Service Station
!
See attached manual „KONVEKTA Service Stations“
D1
S1
S2
S3
S4
S5