Trouble
Trouble
Trouble
Trouble
Cause
Cause
Cause
Cause
Repair
Repair
Repair
Repair
only by refrigeration expert
only by refrigeration expert
only by refrigeration expert
only by refrigeration expert
a/c is not running
thermostat open
•
check inside temperature
•
re-adjust thermostat
electric connections disconnected
•
check electric connections at switchboard
relay defective
•
check relay,replace if necessary
defrost thermostat has switched
off
•
check evaporator blower,replace if neces-
sary
outside temperature too low
(possible icing of evaporator)
•
switch on "ventilation" only
evaporator coil dirty
•
clean evaporator coil with compressed air
magnetic clutch
•
check connections at magnetic clutch
Blinking code in
display
excess pressure (pressure too
high)
•
check axial fans
•
check fuses at switchboard
•
clean condenser coil with compressed air
excess pressure caused by high
outside temperature
•
run unit until pressure has stabilized
leakage in a/c unit, lack of refrig-
erant
•
check a/c unit for leakages, refill refriger-
ant
low pressure, dryer clogged
•
replace dryer
low pressure, screen of expansion
valve clogged
•
clean screen; replace dryer
compressor does not compress
•
check high and low pressure, replace
compressor if necessary
Loud noise at com-
pressor
defective bearing at compressor
•
replace either bearing or entire compres-
sor
slack V-belt
•
check V-belt at compressor drive