KONVEKTA KL40T Operating Instructions Manual Download Page 12

 
 

 

BAKL40T12AE 

Edition: 20.04.2009 

Page: 12/12 

6.

6.

6.

6.

Warranty Conditions

Warranty Conditions

Warranty Conditions

Warranty Conditions    

The current „General Warranty Conditions KONVEKTA AG“ will apply. A copy will be furnished by the 
warranty department. Please contact 

[email protected]

 

    

7.

7.

7.

7.

Waste disposal in accordance with legal provisions

Waste disposal in accordance with legal provisions

Waste disposal in accordance with legal provisions

Waste disposal in accordance with legal provisions    

After the phase of use the last proprietor is responsible for the adequate waste management. The enviro

After the phase of use the last proprietor is responsible for the adequate waste management. The enviro

After the phase of use the last proprietor is responsible for the adequate waste management. The enviro

After the phase of use the last proprietor is responsible for the adequate waste management. The environ-

n-

n-

n-

mental regulations in the exporting country must be observed.

mental regulations in the exporting country must be observed.

mental regulations in the exporting country must be observed.

mental regulations in the exporting country must be observed. 

The following list contains the most important regulating literature, valid for the 

Federal Rep. of Germany

Resolution for dangerous substances 

Resolution for used oil 

Law for waste circulation (KRW/AfgG)) 

Law of water balance 

Resolution for the proofs of utilization and re-
moval 

Resolution for the waste management of old cars and 
the adaptation of road prescriptions 

Criminal Code (StGB) 28

th

 section „criminal 

acts against the environment” §326 – Environ-
ment jeopardizing waste management 

Resolution (EWC) No.3093/94 for materials that af-
fect the ozone layer 

Law of chemicals § 27 – penal prescriptions 

Resolution to prohibit certain ozone destroying halo-
gen hydrocarbons. 

The used refrigerant endangers the environment. When dealing with refrigerants the existing prescriptions 
and regulations are to be followed. Only skilled personnel are

Only skilled personnel are

Only skilled personnel are

Only skilled personnel are allowed to carry out these works!

 allowed to carry out these works!

 allowed to carry out these works!

 allowed to carry out these works!    

Water endangering substances – acc. To §§19g-19l – are solid, liquid, and gaseous substances. E.g.: mineral 
and tar oils (cooling oils), halogen containing organic combinations (refrigerants). 
 
 
 

8.

8.

8.

8.

History of modification

History of modification

History of modification

History of modification    

vers

vers

vers

versiiiion

on

on

on     date

date

date

date    

name

name

name

name    

remark

remark

remark

remark    

file

file

file

file    

A00 

30.05.2007

  B. Keßler  source file 

BAKL40T12AE 

A01 

10.07.2007

  B. Keßler  Added KL45T and technical data 

BAKL40T12AE 

A02 

20.11.2007

  B. Keßler  Item 1.2 has now been replaced 

BAKL40T12AE 

A03 

20.04.2009 

B. Keßler  Point 1.2 updated; TM31 replaced by HDC 33. 

BAKL40T12AE 

 

Summary of Contents for KL40T

Page 1: ...ing Air Conditioning Air Conditioning Air Conditioning unit unit unit unit KL40T KL45T KL40T KL45T KL40T KL45T KL40T KL45T with control KS15 02 with control KS15 02 with control KS15 02 with control KS15 02 Versions Versions Versions Versions 24 Volt DC 24 Volt DC 24 Volt DC 24 Volt DC Recirculated Air Recirculated Air Recirculated Air Recirculated Air Fresh Air Fresh Air Fresh Air Fresh Air ID ID...

Page 2: ...escription and functions of the operating pannel keys 8 4 2 Display indication 8 4 3 Display of outside air temperature optional 8 4 4 AC automatic 8 4 4 1 Manuel adjustment of the evaporator performance 9 4 5 Recirculated air operation 9 4 6 Blinking code in display 9 5 5 5 5 Maintenance Maintenance Maintenance Maintenance Servicing Servicing Servicing Servicing 10 10 10 10 5 1 Oil change Compres...

Page 3: ...wa You will certainly understand that we will not recognize any wa You will certainly understand that we will not recognize any war r r rranty claims due to ranty claims due to ranty claims due to ranty claims due to unproper unproper unproper unproper handling inadequate maintenance a handling inadequate maintenance a handling inadequate maintenance a handling inadequate maintenance ap p p pplica...

Page 4: ...may differ in some parts of description in some parts of description in some parts of description in some parts of description In case your product is equipped with details not shown or described in the operating i In case your product is equipped with details not shown or described in the operating i In case your product is equipped with details not shown or described in the operating i In case y...

Page 5: ...15 000 12 000 18 000 15 000 12 000 Evaporator Evaporator Evaporator Evaporator Air volume Air volume Air volume Air volume free blowing m3 h three stage stageless 4 000 4 400 4 000 4 400 Measurements Measurements Measurements Measurements length length length length mm 1 966 1 966 width width width width mm 1 368 1 836 hight depending on roof hight depending on roof hight depending on roof hight d...

Page 6: ...observance of the Operating instruction and the proof of regular inspections as well 3 3 3 3 Generally information for a c unit Generally information for a c unit Generally information for a c unit Generally information for a c unit Attention in case of roof top a c units Never switch on the a c unit during car Attention in case of roof top a c units Never switch on the a c unit during car Attenti...

Page 7: ...efect neither for corrosion nor for consequential damage resulting there from nor for damages caused by cleaning the systems with highly compressed or corrosion advancing substances 4 4 4 4 Operation Operation Operation Operation Danger of Danger of Danger of Danger of accidents accidents accidents accidents Focussing your attention on the road traffic is of top priority Only operate your air cond...

Page 8: ... room temperature is displayed 4 3 4 3 4 3 4 3 Display of outside air temperatu Display of outside air temperatu Display of outside air temperatu Display of outside air temperature re re re optional optional optional optional Double click key S5 display of outside temperature outside temperature outside temperature outside temperature for approx 5 seconds 4 4 4 4 4 4 4 4 AC AC AC AC automatic auto...

Page 9: ...rculated air operating mode the flow of external air in the vehicle s passenger compartment is blocked and the system recirculates the air existing in the vehicle s interior This keeps the vehicle s environment uncontaminated from polluted air that might be sucked from the outside e g in tunnels This position should not be adjusted very long If windows are misting up return air operation should be...

Page 10: ...1 5 1 5 1 5 1 Oil change Compressor type KVX Oil change Compressor type KVX Oil change Compressor type KVX Oil change Compressor type KVX Reference to maintenance Schedule Bus No WP 07 05 06 18 Item WK15 Reference to maintenance Schedule Bus No WP 07 05 06 18 Item WK15 Reference to maintenance Schedule Bus No WP 07 05 06 18 Item WK15 Reference to maintenance Schedule Bus No WP 07 05 06 18 Item WK1...

Page 11: ...check evaporator blower replace if neces sary outside temperature too low possible icing of evaporator switch on ventilation only evaporator coil dirty clean evaporator coil with compressed air magnetic clutch check connections at magnetic clutch Blinking code in display excess pressure pressure too high check axial fans check fuses at switchboard clean condenser coil with compressed air excess pr...

Page 12: ...aste circulation KRW AfgG Law of water balance Resolution for the proofs of utilization and re moval Resolution for the waste management of old cars and the adaptation of road prescriptions Criminal Code StGB 28th section criminal acts against the environment 326 Environ ment jeopardizing waste management Resolution EWC No 3093 94 for materials that af fect the ozone layer Law of chemicals 27 pena...

Page 13: ......

Page 14: ......

Page 15: ... OFF 25 0 bar 0 5 ON 18 0 bar 0 5 0 5 OFF 25 0 bar 0 1 2 ON 20 0 bar 0 6 0 6 Only for EvoBus with Wabco control X X X X X X X X 4 4 4 4 Check function of low pressure switch LP OFF 0 3 bar 0 1 ON 2 1 bar 0 2 OFF 0 2 bar 0 1 0 2 ON 0 4 bar Only for EvoBus with Wabco control X X X X X X X X 5 5 5 5 Exchange filter drier And after every intervention in the refrigeration circuit X X X X X X X X 6 6 6 ...

Page 16: ...X X X Maintenance Intervals for countries with a moderate Maintenance Intervals for countries with a moderate Maintenance Intervals for countries with a moderate Maintenance Intervals for countries with a moderate climate climate climate climate Maintenance Intervals for cou Maintenance Intervals for cou Maintenance Intervals for cou Maintenance Intervals for countries with a hot ntries with a hot...

Reviews: