KONVEKTA KL40T Operating Instructions Manual Download Page 10

 
 

 

BAKL40T12AE 

Edition: 20.04.2009 

Page: 10/12 

5.

5.

5.

5.

    Maintenance

Maintenance

Maintenance

Maintenance / Servicing

 / Servicing

 / Servicing

 / Servicing    

Service and maintenance works have to be executed on basis of 

“Maintenance Schedule, no: 

WP07050618

---- Only qualified staff is allowed to carry out these works! 

 Only qualified staff is allowed to carry out these works! 

 Only qualified staff is allowed to carry out these works! 

 Only qualified staff is allowed to carry out these works! ----    

For general instructions on repair – and maintenance works please contact via email: 

[email protected]

[email protected]

[email protected]

[email protected]    

    

 Danger of accident!

Danger of accident!

Danger of accident!

Danger of accident!    

The experts in charge of installation and maintenance works should at least be trained in accor-
dance with the EN 378 - part 4 and strictly obey the legal regulations. 
All works or modifications at the air conditioner which are improperly executed can lead to func-
tion troubles and can jeopardize the operation safety. We recommend having works and modifica-
tions only executed in a KONVEKTA service station

 Also the prescribed regular maintenance 

works should be executed in an authorized KONVEKTA service station

Before having the maintenance executed please read carefully the KONVKETA safety prescriptions 
(TD00052A

 ), in order to avoid dangers and accidents! 

    See hand book„KONVEKTA

KONVEKTA

KONVEKTA

KONVEKTA Service Stations 

    Source of supply: KONVEKTA AG

KONVEKTA AG

KONVEKTA AG

KONVEKTA AG, P.O. Box 2280, D-34607 Schwalmstadt 

 

 

 

5.1.

5.1.

5.1.

5.1.

Oil change Compressor type KVX

Oil change Compressor type KVX

Oil change Compressor type KVX

Oil change Compressor type KVX    

Reference to maintenance Schedule Bus No.: WP 07 05 06 18 Item WK15:

Reference to maintenance Schedule Bus No.: WP 07 05 06 18 Item WK15:

Reference to maintenance Schedule Bus No.: WP 07 05 06 18 Item WK15:

Reference to maintenance Schedule Bus No.: WP 07 05 06 18 Item WK15:    

First oil change at the first maintenance of the vehicle, then approx. every 3 years. At every oil change the 
oil  suction  strainer  has  to  be  cleaned.  Observe  the  oil  quantity  according  to  the  compressor  type  (see 
chapter: “Technical data compressor”). 

5.2.

5.2.

5.2.

5.2.

Return air grid

Return air grid

Return air grid

Return air grid    

Reference to Maintenance Schedule Bus No.: WP 07 05 06 18 Item WK13:

Reference to Maintenance Schedule Bus No.: WP 07 05 06 18 Item WK13:

Reference to Maintenance Schedule Bus No.: WP 07 05 06 18 Item WK13:

Reference to Maintenance Schedule Bus No.: WP 07 05 06 18 Item WK13:    
Clean the return air grid in the passenger area monthly, in case of enormous dirt weekly. 

5.3.

5.3.

5.3.

5.3.

Condenser coil

Condenser coil

Condenser coil

Condenser coil    

Reference 

Reference 

Reference 

Reference to Maintenance Schedule Bus No.: WP 07 05 06 18 Item WK03:

to Maintenance Schedule Bus No.: WP 07 05 06 18 Item WK03:

to Maintenance Schedule Bus No.: WP 07 05 06 18 Item WK03:

to Maintenance Schedule Bus No.: WP 07 05 06 18 Item WK03:    

Always keep condenser coil fins clean. Severe soiling cause’s excess pressure within the a/c-unit system and 
it automatically stops working.  
Attention: 

Attention: 

Attention: 

Attention: The condenser coil fins have to be cleaned with compressed air at least once a year, in case of 
severe soiling more often. 

Summary of Contents for KL40T

Page 1: ...ing Air Conditioning Air Conditioning Air Conditioning unit unit unit unit KL40T KL45T KL40T KL45T KL40T KL45T KL40T KL45T with control KS15 02 with control KS15 02 with control KS15 02 with control KS15 02 Versions Versions Versions Versions 24 Volt DC 24 Volt DC 24 Volt DC 24 Volt DC Recirculated Air Recirculated Air Recirculated Air Recirculated Air Fresh Air Fresh Air Fresh Air Fresh Air ID ID...

Page 2: ...escription and functions of the operating pannel keys 8 4 2 Display indication 8 4 3 Display of outside air temperature optional 8 4 4 AC automatic 8 4 4 1 Manuel adjustment of the evaporator performance 9 4 5 Recirculated air operation 9 4 6 Blinking code in display 9 5 5 5 5 Maintenance Maintenance Maintenance Maintenance Servicing Servicing Servicing Servicing 10 10 10 10 5 1 Oil change Compres...

Page 3: ...wa You will certainly understand that we will not recognize any wa You will certainly understand that we will not recognize any war r r rranty claims due to ranty claims due to ranty claims due to ranty claims due to unproper unproper unproper unproper handling inadequate maintenance a handling inadequate maintenance a handling inadequate maintenance a handling inadequate maintenance ap p p pplica...

Page 4: ...may differ in some parts of description in some parts of description in some parts of description in some parts of description In case your product is equipped with details not shown or described in the operating i In case your product is equipped with details not shown or described in the operating i In case your product is equipped with details not shown or described in the operating i In case y...

Page 5: ...15 000 12 000 18 000 15 000 12 000 Evaporator Evaporator Evaporator Evaporator Air volume Air volume Air volume Air volume free blowing m3 h three stage stageless 4 000 4 400 4 000 4 400 Measurements Measurements Measurements Measurements length length length length mm 1 966 1 966 width width width width mm 1 368 1 836 hight depending on roof hight depending on roof hight depending on roof hight d...

Page 6: ...observance of the Operating instruction and the proof of regular inspections as well 3 3 3 3 Generally information for a c unit Generally information for a c unit Generally information for a c unit Generally information for a c unit Attention in case of roof top a c units Never switch on the a c unit during car Attention in case of roof top a c units Never switch on the a c unit during car Attenti...

Page 7: ...efect neither for corrosion nor for consequential damage resulting there from nor for damages caused by cleaning the systems with highly compressed or corrosion advancing substances 4 4 4 4 Operation Operation Operation Operation Danger of Danger of Danger of Danger of accidents accidents accidents accidents Focussing your attention on the road traffic is of top priority Only operate your air cond...

Page 8: ... room temperature is displayed 4 3 4 3 4 3 4 3 Display of outside air temperatu Display of outside air temperatu Display of outside air temperatu Display of outside air temperature re re re optional optional optional optional Double click key S5 display of outside temperature outside temperature outside temperature outside temperature for approx 5 seconds 4 4 4 4 4 4 4 4 AC AC AC AC automatic auto...

Page 9: ...rculated air operating mode the flow of external air in the vehicle s passenger compartment is blocked and the system recirculates the air existing in the vehicle s interior This keeps the vehicle s environment uncontaminated from polluted air that might be sucked from the outside e g in tunnels This position should not be adjusted very long If windows are misting up return air operation should be...

Page 10: ...1 5 1 5 1 5 1 Oil change Compressor type KVX Oil change Compressor type KVX Oil change Compressor type KVX Oil change Compressor type KVX Reference to maintenance Schedule Bus No WP 07 05 06 18 Item WK15 Reference to maintenance Schedule Bus No WP 07 05 06 18 Item WK15 Reference to maintenance Schedule Bus No WP 07 05 06 18 Item WK15 Reference to maintenance Schedule Bus No WP 07 05 06 18 Item WK1...

Page 11: ...check evaporator blower replace if neces sary outside temperature too low possible icing of evaporator switch on ventilation only evaporator coil dirty clean evaporator coil with compressed air magnetic clutch check connections at magnetic clutch Blinking code in display excess pressure pressure too high check axial fans check fuses at switchboard clean condenser coil with compressed air excess pr...

Page 12: ...aste circulation KRW AfgG Law of water balance Resolution for the proofs of utilization and re moval Resolution for the waste management of old cars and the adaptation of road prescriptions Criminal Code StGB 28th section criminal acts against the environment 326 Environ ment jeopardizing waste management Resolution EWC No 3093 94 for materials that af fect the ozone layer Law of chemicals 27 pena...

Page 13: ......

Page 14: ......

Page 15: ... OFF 25 0 bar 0 5 ON 18 0 bar 0 5 0 5 OFF 25 0 bar 0 1 2 ON 20 0 bar 0 6 0 6 Only for EvoBus with Wabco control X X X X X X X X 4 4 4 4 Check function of low pressure switch LP OFF 0 3 bar 0 1 ON 2 1 bar 0 2 OFF 0 2 bar 0 1 0 2 ON 0 4 bar Only for EvoBus with Wabco control X X X X X X X X 5 5 5 5 Exchange filter drier And after every intervention in the refrigeration circuit X X X X X X X X 6 6 6 ...

Page 16: ...X X X Maintenance Intervals for countries with a moderate Maintenance Intervals for countries with a moderate Maintenance Intervals for countries with a moderate Maintenance Intervals for countries with a moderate climate climate climate climate Maintenance Intervals for cou Maintenance Intervals for cou Maintenance Intervals for cou Maintenance Intervals for countries with a hot ntries with a hot...

Reviews: