EAKL2E132AA
Edition: 26.04.2012
Page: 11/18
5.1.1.
Installation of fan switch in the air distribution plate
Close one of the two existing holes in the air distribution plate with the rubber nozzle, Art. No.: H14-000-
260, label the other one with the label H25-001-063 for the fan switch.
Attention:
Attention:
Attention:
Attention: 0 position (OFF) of the fan switch and 0-position of the label have
to match!
OFF - off
LOW - slow
MED - medium
HI
- fast
Unplug the button with the clip at the fan switch; fit the switch with the two nuts which were delivered
together with the switch to the air distribution plate. Then put the button including the clip back to the
switch.
BB-ZW0-050
Button with spring
Rubber grommet
H14-000-260
Blower switch
B11-AA0-432
H14-000-260
H25-001-063
Nut for fastening the
blower switch
Nut for fastening the
blower switch