Starting Up
6.1.
DC Power Terminal
The FusionView is delivered with a DC power plug terminal (3-pin Phoenix connector). For DC connection, prepare the
connecting wires using the supplied Phoenix plug terminal: PSC 1,5/ 3-F.
Figure 31: Phoenix power plug terminal
1.
3-pin Phoenix plug terminal
2.
Cover over the slotted pan head screws
3.
Location for inserting the "15-30 V DC
(input)" wire
4.
Location for inserting the
“shield” wire
5.
Location for inserting the “0 V
(input)” wire
6.1.1.
Cabling
For the pin assignment Phoenix power plug terminal refer to subsection 8.1.1 “Power Input Connector”.
1.
Cut the required length three isolated wires (1 mm
2
) American Wire Gauge (AWG18) and strip each end 5 to 7 mm.
2.
Twist the striped wire-ends and provide them with ferrules.
3.
Open the cover (Figure 31, pos. 2) to have access to the slotted pan head screws.
4.
Loosen the slotted pan head screws of the DC plug terminal far enough so that you can insert the end of the
prepared wires.
5.
Insert the wires into the corresponding clamp of the Phoenix plug terminal. Make sure that you have the right
polarity of the connection [refer to Figure 31, Figure 24 or subsection 8.1.1 “Power Input Connector”].
6.
Fasten the screws to secure the wires into the clamps of the plug terminal.
7.
Close the cover (Figure 31, pos. 2).
4