www.ks-power.de/en
|
7
Model
KS 8100HDE-1/3 ATSR (EURO V)
KS 8102HDE-1/3 ATSR (EURO II)
KS 9100HDE-1/3 ATSR (EURO V)
KS 9102HDE-1/3 ATSR (EURO II)
Voltage, V
230
400
230
400
Max Power, kW
5.5
6.5
6.5
7.5
Nominal Power, kW
5.0
6.0
6.0
7.0
Frequency, Hz
50
50
50
Current max, A
23.91
11.74
28.26
13.54
Outlets
1*32А, 1*16А (3p)
1*32А, 1*16А (3p)
Fuel tank volume, l
11
11
50% power working time, h*
6.9
6.1
LED display
voltage, frequency, working hours
Noise level L
PA
(7m)
/L
WA
, dB
71/96
71/96
Power output V/А
12/8.3
12/8.3
Engine model
EURO II
KS 480HD
EURO V
KS 480HD-V
EURO II
KS 520HD
EURO V
KS 520HD-V
Engine type
diesel powered one-cylinder, four-stroke air-cooled
Engine power, hp
14.0
18.0
Crank case volume, cm
3
1.65
1.65
Engine cylinder volume cm
3
456
498
Power output controller
AVR
AVR
Fuel heater
+
+
Engine start
manual/electro
manual/electro
Power factor, cosφ
1.0 (230V)
0.8 (400V)
1.0 (230V)
0.8 (400V)
Housing
reinforced steel frame 32 mm
Battery, Ah
30
30
Output for ATS
+
+
Dimensions (L*W*H), mm
730x495x630
730x495x630
Net weight, kg
117
122
Protection class
IP23M
IP23M
IP23M
Altitude (MAX), m
1000
1000
1000
Relative humidity
<95%
<95%
<95%
Acceptable deviation of a current is 10%
*Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical
condition of the generator.
LwA
is sound power level. This indicator is measured in the immediate vicinity of the noise maker.
LpA
is sound pressure level. This indicator is calculated as a function of the distance between the
operator and the noise source. At a distance of 7 m: LpA (7) dB = (LwА - 25) dB
The optimum operating conditions are ambient temperature of 17°C – 25°C, barometric pressure of 0.1
MPa (760 mm Hg), and relative humidity of 50 – 60%. Under such ambient conditions, the generator can
guarantee maximum performance in terms of the stated specifications. In case of deviations from the above
ambient values, the performance of the generator can be different.
Please note that in order to preserve the lifespan of the generator, continuous loads should not exceed
80% of the rated power.
Summary of Contents for KS 6100HDE
Page 22: ......