www.ks-power.de/en
|
18
POSSIBLE FAILURES AND SOLUTIONS
17
Typical failures
Possible reason
Варіант усунення
Engine does not
start
Engine starting swich set to OFF
position
Set the engine starting switch to ON
No fuel
Add fuel
Low-quality or dirty
fuel is in engine
Change the fuel
Low engine power /
heavy starting
Dirt in fuel tank
Clean the fuel tank
Air filter is dirty
Change the air filter
Water or air in the fuel line
Pump the fuel line
Engine is overheated
Cooling fins are dirty
Clean the cooling fins
Air filter is dirty
Change the air filter
No voltage while
engine is working
Circuit breaker is active
Turn on the circuit breaker
Connected cables are corrupted
Check the cables;
if using extension cord, change it
Plugged device failure
Try to connect other devices
Connected devices
are not working
while generator is
running
Generator is overloaded
Unplug some devices to reduce
load
Short circuit occurred in one of the
devices connected
Unplug that device to restore the
stability of a system
Air filter is dirty
Change the air filter
Repetitions of an engine are lower
than nominal
Contact the service center
To prevent electric shock and avoid damage to your elec-
tric devices and generator, simultaneous switching on of
three and one phase circuit breaker is prohibited!
ATTENTION - DANGER!