Konica Minolta SC-508 Installation Manual Download Page 8

E-8

(11) Reinstall the dual scan board removed in step 

(7). (Two screws)

(12) Install two supplied shoulder screws (large).

(13) Connect the connector which was removed in 

step (6) again.

(14) Insert the supplied DSC board to the indicated 

connector of the dual scan board horizontally 
until it hits against the end.

Note:

Perform it with certainty because contact failure 
leads to the breakage of the board.

(15) Tighten the supplied screw and the screw 

removed in step (7).

(16) To install the covers and other parts removed in 

steps (2) to (4), reverse the removal procedure.

3. Configuration procedures

<Setting the security kit>

(1) Plug the power cord into the power outlet and 

turn ON the power switch.

(2) Display the Service Mode screen.

(For details of how to display the Service Mode 
screen, see the service manual.)

(3) Touch “System 2.”
(4) Touch “Option Board Status.”
(5)
<When attaching one DSC board>

Touch “Set” of DSC1.

<When attaching two DSC boards>

Touch “Set” of DSC1 and DSC2.

(6) Touch “END.”

<Security setting>

Note:

The following setting should be performed by the 
Administrator.

(1) Touch the [Menu] key.
(2) Select the function to be used as follows:

Utility

 Administrator Settings 

 Enter the 

Administrator Password 

 Forward 

 Security 

Settings 

 Security Details

(3) Touch “

” two times.

(4) Touch “Copy Guard.”
(5) Touch “Yes.”
(6) Touch “Password Copy.”
(7) Touch “Yes.”
(8) Touch “OK.”
(9) Turn OFF and ON the power switch.

Summary of Contents for SC-508

Page 1: ...4 Used only when the Dual Scan Document Feeder is installed to the machine Note Two security kits are required for the following models which have the Dual Scan Document Feeder C754e C654e C754 C654 C554e C454e C554 C454 754e 654e 754 654 554e 454e C368 C308 With DF 704 C364e C284e C224e C364 C284 C224 364e 284e 224e With DF 701 If none of the later steps instruct you to use the parts including sc...

Page 2: ...ual Scan Docu ment Feeder or the Upgrade Kit UK 209 go to When the machine has the dual scan board on page E 3 When the machine does not have the Dual Scan Document Feeder or the Upgrade Kit UK 209 perform the following steps 3 Insert the supplied DSC board to the indicated connector of the machine horizontally until it hits against the end Note Perform it with certainty because contact failure le...

Page 3: ... cover removed in step 2 C754e C654e C754 C654 C554e C454e C364e C284e C224e 754e 654e 754 654 554e 454e 364e 284e 224e Six screws C554 C454 C364 C284 C224 10 screws 8 Go to 3 Configuration procedures on page E 8 When the machine has the dual scan board 3 Remove the indicated connector from the dual scan board Note Perform this step only when the dual scan docu ment feeder is installed 4 Remove th...

Page 4: ... fasten the board holder to the machine Note Make sure that the DSC board does not slant If it slants push it horizontally until it hits against the end 10 Reinstall the dual scan board removed in steps 4 to 5 by reversing the removal procedure Note Perform the following steps 11 to 14 only when the dual scan document feeder is installed 11 Connect the connector which was removed in step 3 again 1...

Page 5: ...slant If it slants push it horizontally until it hits against the end 15 Attach the cover removed in step 2 on E 2 C754e C654e C754 C654 C554e C454e C364e C284e C224e 754e 654e 754 654 554e 454e 364e 284e 224e Six screws C554 C454 C364 C284 C224 10 screws 16 Go to 3 Configuration procedures on page E 8 Installations to models C368 C308 1 Turn OFF the power switch and unplug the power cord from the...

Page 6: ...he supplied DSC board into the connector shown of the machine straight all the way until it is stopped Note Perform it with certainty because contact failure leads to the breakage of the board 8 Install two supplied shoulder screws large 9 Tighten the supplied screw at the position shown in the illustration 10 Affix the supplied gasket on the back of the lower rear cover while aligning with the ma...

Page 7: ...r from the dual scan board 7 Remove the dual scan board Two screws 8 Remove the two screws shown in the illustration from the machine 9 Install two supplied shoulder screws small 10 Insert the supplied DSC board into the connec tor shown of the machine straight all the way until it is stopped Note Perform it with certainty because contact failure leads to the breakage of the board ...

Page 8: ...cedures Setting the security kit 1 Plug the power cord into the power outlet and turn ON the power switch 2 Display the Service Mode screen For details of how to display the Service Mode screen see the service manual 3 Touch System 2 4 Touch Option Board Status 5 When attaching one DSC board Touch Set of DSC1 When attaching two DSC boards Touch Set of DSC1 and DSC2 6 Touch END Security setting Not...