E-10
(2) Align the bottom holes of the front cover with
the pins of the power supply unit, and use the
temporarily placed screws to secure it.
Note:
If the front cover does not close because it touches
the machine or optional unit, adjust the horizontal
position or angle of the front cover. If the actuator
does not turn the interlock switch ON, adjust the
position of the actuator adjustment plate as well.
19. Plug in the power cord.
Connect the power cord to the RU-504 and plug
it into the outlet. (included in the machine pack-
age)
* For the installation procedure for the RU-504,
see the RU-503/504 installation manual.
1. Turn OFF the machine's Sub and Main power
switches, and unplug the power cord.
2. Install the Installation plate/1 (2 places), the
Installation plate/2, and the Installation plate/3 on
the left side of the LS-501 as below. (TP screw
M4x6: each 2 pcsx4 places.)
Note:
For the Installation plate/2 and the Installation
plate/3, use the screw holes with the engraved
marking “FS503”.
15AQIXE0
6
1SA
Pin
Pin
Loosen the
screws to
adjust the
horizontal
position
Actuator adjustment plate
Loosen the screw to adjust the angle
Loosen the screw to
adjust the horizontal position
15AQIXF0
62
SA
Installation procedure for
[FS-503 + LS-501 + MFP 105ppm series]
[FS-503 + LS-501 + RU-504
+COLOR MFP 65ppm series]
Machine
15AEIXE045SA
FS-503
RU
-504
Power cord
15AEIXE018SA
Installation plate/1
Installation plate/
2
Installation plate/3
Engraved marking FS503