T-3
(4)
Motors
Step
Check
Result
Action
1
Is the LOCK signal of the Controller/Mechanical Con-
trol Board HIGH when the printer is in the standby
state?
NO
Replace the Con-
troller/Mechanical
Control Board.
Replace the motor.
2
Does the REM signal of the Controller/Mechanical
Control Board go from HIGH to LOW when the motor
is energized?
YES
Replace the motor.
NO
Replace the Con-
troller/Mechanical
Control Board.
Step
Check
Result
Action
1
Does the input signal to the Controller/Mechanical
Control Board go from HIGH to LOW when the motor
is energized? (The input signal varies depending on
the direction of rotation.)
YES
Replace the motor.
NO
Replace the Con-
troller/Mechanical
Control Board.
4025T526AA
GND
REM
LOCK
2
1
3
4025T525AA