Using tweezers, remove the stamp
cartridge [1].
3.4
Cleaning procedure
NOTE
• The alcohol described in the cleaning procedure of maintenance represents the
isopropyl alcohol.
3.4.1
White sheet
1.
Open the auto document feeder unit.
2.
Clean the white sheet [1].
3.4.2
Registration sensor
1.
Open the auto document feeder unit.
2.
Using a cotton swab or rod-shaped
cloth, wipe the registration sensor [1]
clean of dirt.
A0EYF2C512DA
[1]
A0EYF2C508DA
[1]
A0EYF2C516DA
[1]