5. Service Mode
Field Service Ver. 1.0 Jun. 2008
DF-612/SP-503/MS-501
Adjustment / Setting
4.
Select the appropriate function according to what needs to be checked and adjusted.
• <1st side>
Original placement: Printed side up, arrow pointing to the leading edge
Simplex/Duplex: [1 > 1]
• <2nd side>
Original placement: Printed side down, arrow pointing to the trailing edge
Simplex/Duplex: [2 > 2]
• <3rd side>
Original placement: Printed side up, arrow pointing to the leading edge
Simplex/Duplex: [2 > 2]
Mixed Original: [ON]
* Copy paper A4S or letterS, auto zoom, mixed original
5.
Measure width A and width B on the
test chart and the copy to determine
if the difference in the width falls
within the specified range.
6.
If the difference in the width of a falls
outside the specified range, make
the following adjustment.
7.
Touch [OK].
8.
Touch [ADF Adjustment]
o
[Feed].
9.
Touch the function to be adjusted
and touch either [+] or [-] whichever
is applicable. Then, enter the
numeric data from the 10-key pad.
• If the width A on the copy is longer
than that on the chart, enter a positive
value using + key.
• If the width B on the copy is longer
than that on the chart, enter a positive
value using + key.
10.
Touch [OK].
11.
Press the Reset key.
12.
Repeat steps 3 to 11 until the difference in the width falls within the specified range.
13.
Touch [OK] on the Service Mode screen.
14.
Turn OFF the main power switch, then wait for 10 sec. or more and turn ON the main
power switch.
A
B
A0EYF3C503DA
A0EYF3E511DA
36
Service Manual Y109
850
-
7