7
Assembly Instructions -
SUC Unit
For proper assembly, follow steps below. See Figure 3,
Page 6.
a: Attach the 4 leg extensions (Item A) to the bottom
of the POLYVAC stand. Requires 16, 1/4 x 3/4"
bolts.
b: If the POLYVAC unit is to be mobile, attach the 4
optional caster wheels (Item B). Requires
4, 1/4 x 3/4" bolts.
c: Mount the Blow Through Unit (Item C) on the bot
-
tom of the Rotary Valve (Item D). Requires
4, 5/16 x 2" bolts.
d: Mount the POLYVAC unit in a suitable location
using the bolt plate on the legs of the stand.
Make certain that the foundation is secure,
and check regularly that all mounting bolts
are tight.
e: Rotate the Cyclone Inlet (Item E) for the best work
-
ing position of the Suction Flex hose. Loosen, but
do not remove, the clamps on both top and bottom
of the cyclone. Rotate the cyclone to the desired
position, and retighten the clamps.
f: Attach the Variable Air Intake (Item F) to the Cy
-
clone with OK160 (6") clamp.
g: Install the 4" Suction Flex hose. (Item H) Clamp the
OK160 (6") to OK100 (4") adapter (Item G) to the
variable air intake. Then connect the Flex hose with
the OK100 (4") clamp.
h: Install the Suction Wand (Item I) to the Flex hose.
The air intake and handle are locate at the end nea
-
rest the hose.
i: Install the Intermediate Piping (Item J to L) between
the Fan outlet and the Blow Through Unit.
1: Attach the 90° Degree (Item J) elbows to the
Fan outlet and to the Blow Through using the
clamps.
2: Slide the telescopic pipe with rubber O'Ring
(Item K) inside the 12" pipe (Item L).
Note:
The seams of the pipe must be aligned
for proper function of the telescopic pipe.
3: Mount the telescopic pipe between the elbows
adjusting the pipe to the desired length. Se
cure both ends with the pipe clamps.
4: Slide the rubber O'Ring down the pipe until it
rests on the other pipe lip. Place the pipe
clamp around O'Ring and the pipe lip, and
secure clamp.
j: Install electrical power to the motor. Follow electri
-
cal wiring instructions on the inside of motor electri-
cal box.
Note:
Make sure the motor is turning in the
proper direction as shown by the the arrow on
the fan housing.
All electrical work must comply with local
regulations.
Summary of Contents for POLYVAC 30
Page 1: ...POLYVAC Pneumatic conveying system Directions for use ...
Page 2: ...2 POLYVAC 30 50 Standard units with Gaylord height stand and dust collection Fig 1 ...
Page 4: ...4 POLYVAC 30 50 Standard Units with Suction Flexhose Fig 2 ...
Page 6: ...6 POLYVAC 30 50 SUC Unit Fig 3 ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 15: ...15 ...