26
492671/C
specifications for the actual "shunt capacitance". A common figure is 47.5 pF/m, which
gives a maximum cable length of about 50 meters.
Even though a standard exist for RS-232 pin configuration, certain manufacturer may still
choose their own connector pins for the various signals used. In order to make the RS-232
connection to your peripheral device work properly, you must always consult the relevant
instructions provided by the device manufacturer.
Pin configuration
Moxa CP114EL-I connectors / Adapter cable
Pin
RS-232
RS-422
RS-485 (4-wire)
RS-485 (2-wire)
1
DCD
TXD-(A)
TXD-(A)
2
RxD
TXD+(B)
TXD+(B)
3
TxD
RXD+(B)
RXD+(B)
Data-(B)
4
DTR
RXD-(A)
RXD-(A)
Data-(A)
5
Ground
Ground
Ground
Ground
6
DSR
-
-
-
7
RTS
-
-
-
8
CTS
-
-
-
9
-
-
-
Minimum cable requirements
•
Conductors
: 2 x 5 x 0.5 mm
2
•
Screen
: Overall braided
•
Voltage
: 60 V
•
Maximum outer diameter
: Defined by the plugs and/or the gable gland
If you wish to use RS-422 or RS-485 serial communication, use a cable with twisted pairs.
If you need to install a very long cable, increase the cross section.